Nexus 3064 (N3K-C3064PQ-10GX): third-party SFP+ and DACs need no negotiate auto and duplex full, or the link never appears or flaps
Setting up an N3K-C3064PQ-10GX on NX-OS 7.0.3.I4.6 with non-Cisco SFP+ modules and DAC cables up to 5 m to servers: after service unsupported-transceiver some ports still show no link, or the link disappears after a while, and one port endd in 'Error disabled. Reason: Too many link flaps'. Which interface settings help?
Comments 2
For the stated NX-OS release, the reported third-party SFP+/DAC configuration disabled negotiation with
no negotiate autoand selectedduplex full. Check the actual port setttings rather than stopping after the global module override.Ports 1-48 default to 10G, so a 1G optic needs an explicit
speed 1000. The same configuration also disabled send and receive fllow control. Keep a copy of the interface configuration when comparing a stable port with one that flaps.