CodingBox Q&A Ask question

Nexus 9364D-GX2A: 400G/100G ports show Link not connected on NX-OS 10.2(x) (FN74074)

Asked Active Viewed 30 Original language: English
0

On an N9K-C9364D-GX2A some of the 64 front-panel QSFP-DD ports stay in 'Link not connected' (for example Eth1/13 down Link not connected auto(D)) even though cables and transceivers are known good; the SFP+ ports Eth1/65-66 and the mannagement port work. Are the optics at fault?

Comments 2

Check FN74074 / CSCwf85943 against the installed release. The notice describes older ASIC firmware in the NX-OS 10.2(x) train causing intermittetn link-up failures on the C9364D-GX2A front-paneel ports.

3 United Statesporttech22US Original (English)

The notice gives a software upgrade to the applicable 10.3(x), 10.4(x) or later train as the remedy, with no configuration workaround. Healthy management and SFP+ ports do not rule out this specific 400G/100G port issue.

3 Netherlandsoptichub40NL Original (English)
Log in to comment. Log in