On an N9K-C9364D-GX2A some of the 64 front-panel QSFP-DD ports stay in 'Link not connected' (for example Eth1/13 down Link not connected auto(D)) even though cables and transceivers are known good; the SFP+ ports Eth1/65-66 and the mannagement port work. Are the optics at fault?
Comments 2
Check FN74074 / CSCwf85943 against the installed release. The notice describes older ASIC firmware in the NX-OS 10.2(x) train causing intermittetn link-up failures on the C9364D-GX2A front-paneel ports.
The notice gives a software upgrade to the applicable 10.3(x), 10.4(x) or later train as the remedy, with no configuration workaround. Healthy management and SFP+ ports do not rule out this specific 400G/100G port issue.