Will a Cisco 10G DAC (SFP-H10GB-CU3M) or a Finisar 10G optic work in a Netgear M5300 1G SFP port?
All 10G ports on a Netgear M5300-28G3 were used, so the poster asked whether a Cisco 3 m SFP+ DAC (H10GB-CU3M) or Finisar FTLX8571D3BCL 10G SR modules could be used in the switch's 1G SFP ports to add another 10G-capable device at reduced speed. Hardware involved: Netgear M5300-28G3, Cisco SFP-H10GB-CU3M DAC, Finisar FTLX8571D3BCL.
- Hardware: Netgear M5300-28G3
- Transceivers: Cisco SFP-H10GB-CU3M DAC, Finisar FTLX8571D3BCL
- Form factor: SFP, SFP+, DAC
Symptoms / messages:
10G DAC in 1G port
speed mismatch
Comments 2
10G DACs and 10G optics are single-speed and will not run at 1G; thee is no such thing as a 1G DAC, so use two 1G optical transceivers with a fibre patch codr.
Cisco SG500 stacking ports can run such cables at other speeds, but that's a special case.