CodingBox Q&A Ask question

All questions

Latest questions from the community.

354 questions
15 30 50 per page
1vote
1comment
72views

SFP Doctor: open hardware/software to read and rewrite SFP OUI and identity when write access is not locked

An open-source hardware and software project to read and modify SFP/SFP+ EEPROM, aimed at changing the OUI and other identity fields so a module works with third-party transceivers where the vendor has not fully disabled write access. It uses a Cypress CY8CKIT-059 board as the USB interface. As of…

2votes
1 answer
100views

Cisco module signature: bytes 96-127 must match the serial number or a recoded SFP is rejected

Discussion of why re-coded modules fail Cisco validation: Cisco SFPs carry a unique signature tied to each serial number in bytes 96-127, and editing vendor name or serial makes the signature no longer match, so the switch rejects the module unless the signature is regenerated. Hardware involved…

2votes
1 answer
107views

sfp-eeprom-tool: CH341A-based SFP EEPROM reader and I2C sniffing to expose silent write failures

A small toolset that reads and writes SFP EEPROM over I2C with a CH341A programmer plus an I2C sniffer. The author found that sigrok/PulseView did not work with the analyser, that a v1.0.5 SFP coder firmware reported success while silently not writing the module (proven by I2C traces), and that the…

1vote
1 answer
66views

How the SFP Wizard unlocks modules (part-number database plus brute force) and why not to downgrade the firmware

Reverse-engineering notes on the SFP Wizard: it reads a module's part number (page A0h bytes 40-55), looks it up in an embedded password database and sends the matching unlock password, falling back to brute force when unmatched. It traces the firmware evolution: v1.0.5 tried only the first…

0votes
1 answer
54views

Writing to password-protected SFP/QSFP/XFP: where the password lives and how brute force works

Users needed to write to password-protected SFP/QSFP/XFP modules from HP, Cisco, Finisar and JDSU. The thread documents the two protection levels: a host/user password protecting the user-writable area (A2h offset 7Bh on SFP, A0h offset 7Bh on QSFP/XFP) and a manufacturer password protecting the…

1vote
1comment
32views

Aruba Instant On 1930 24+4SFP: all SFP ports dead after a power outage, LED blinks once and stops

After a power outage an Aruba Instant On 1930 (24 ports plus 4 SFP) still recognised inserted SFP modules but every SFP port stayed down; inserting a new transceiver made the port LED blink once and then nothing. The poster asked for diagnostics or replacement options. Hardware involved: Aruba…

2votes
2comments
111views

Meraki MX95 WAN2 SFP will not link to an Extreme switch (but does to Netgear): power cycle after inserting the SFP

A Meraki MX95's WAN2 SFP would not link to an upstream Extreme switch, while the same SFP and patch linked to a Netgear switch, which in turn linked to the Extreme. The same happened with an MX85 against an AT&T-provided Ciena device. Cisco-certified and Extreme-certified SFPs were tried in all…

Egypt nethawk74 EG asked
4votes
2comments
48views

HL15 (Supermicro X11SPH, Intel X722) to a UniFi USW-24-POE: every DAC and SFP fails, BIOS reports SFP not recognised

A pre-built HL15 server (Supermicro X11SPH-nCTPF wth Intel X722 SFP+ ports, Rocky Linux) would not link to a UniFi USW-24-POE over a VANDESAIL SFP+ DAC: the switch port stayed Disconnected under every negotiation setting on both sides. After ordering a 10Gtek cable the host reported network driver…

1vote
1comment
50views

Cannot write to Finisar SFPs with REVELPROG: manufacturer password protection and per-power-up entry

The poster could read and write OEM SFP variants with a REVELPROG and SFP adapter but not three Finisar references, suspecting manufacturer password protection. Finisar only documents the MSA user-EEPROM password in datasheets, not the proprietary manufacturer password, and the same happened with…

2votes
1 answer
104views

OPNsense 22.7: interface is disabled due to unsupported sfp on a 10G port, and the Linux ixgbe tunable does not apply

After upgrading OPNsense from the 21.x series to 22.7 a 10G SFP+ port stopped working with interface is disabled due to unsupported sfp; the newer Intel driver actively disables unrecognised modules. The poster tried to set ixgbe.allowunsupportedsfp=1 as a system tunable, which was not accepted…

2votes
1 answer
50views

IBM Emulex dual-port 10GbE SFP+ card hangs TrueNAS and Windows at boot and never shows an active link

A used IBM Emulex dual-port 10GbE SFP+ PCIe card (bent bracket, loose heatsink) made both TrueNAS Core and a Windows 10 PC hang for a long time during boot; the switch showed a link but neither OS saw the interface as active. Hardware involved: IBM Emulex dual-port 10GbE SFP+, Chelsio NICs, Intel…

0votes
1 answer
82views

Alta Labs Route 10 SFP+ ports detect FS.com and 10Gtek DACs but never link; SR optics work at 10G

On an Alta Labs Route 10 the SFP+ ports recognised FS.com SFP-H10GB-CU2M and 10Gtek CAB-10GSFP-P2M DACs (which had worked on MikroTik CRS devices) but no link came up against a MikroTik CRS309-1G-8S+; forcing 1G baseT full gave a 1 Gbps link only. Staff requested diagnostics and ethtool -I output…

1vote
1 answer
54views

Chelsio S320E and a Dell PowerConnect 6224 over a QSFPTEK 0.5 m DAC: no carrier, cable works switch-to-switch

A Chelsio CC2-S320E-SR (110-1114-30) dual-port SFP+ card recognised by TrueNAS would not link to a Dell PowerConnect 6224 through a QSFPTEK 0.5 m passive DAC: no link lights and status: no carrier, even after assigning IPs to cxgb0/cxgb1. Looping the DAC between two switch ports worked, and looping…

2votes
1 answer
65views

OPNsense on a budget C3758R appliance: four ix interfaces, SFP+ ports show down with an RJ45 module

On an inexpensive firewall appliance (Intel Atom C3758R, six 1GbE igc ports and two SFP+ cages wired to the CPU) OPNsense showed four ix interfaces instead of two and the SFP+ ports stayed red/down with a copper SFP+ RJ45 module, although the link LEDs lit. ifconfig -v identified ix0/ix1 as the…

0votes
1comment
122views

OPNsense on a Lanner NCA-1510 does not detect the two Intel I210 fibre SFP interfaces that pfSense sees

On a Lanner NCA-1510 the four Intel X553 ports (ix0-ix3) worked, but two Intel I210 Gigabit Fiber Network Connection interfaces (device 0x15368086) with SFP cages were absent in OPNsense even after loading ifigb via tunables; pfSense detected them by default. Another user had the same with a…

2votes
1comment
51views

TP-Link TL-SM311LM to a SkyLane SFP in a Netgear GS716T: TP-Link side up, Netgear side down, 1 Mbps throughput

A TP-Link T1700G-28TQ (V3, firmware 3.0.0) with a TL-SM311LM module was linked to a Netgear ProSafe GS716T with a SkyLane SFP85P55GE0B989 module. The TP-Link port showed 1000M with a flashing LED while the Netgear port stayed down, and throughput was about 1 Mbps; with a media converter the link…

0votes
1comment
63views

Genuine versus third-party SFP/SFP+ on Extreme switches: DDMI not readable on an X620, no vendor support

The poster had free thrid-party SFP/SFP+ samples that worked on Extreme switches and asked whether to buy genuine or third-party modules. A respondent reported that on a new X620 a third-party SFP+ linked but its DDMI data could not be read, and that Extreme provides no help for problems involving…

2votes
1 answer
110views

FortiGate 500E shows This port is using a third-party transceiver: warning or error?

A FortiGate 500E displayed the message This port is using a third-party transceiver on an SFP+ port; the poster asked whta it meant and which SFP+ specification to use. There were no errors or link problems, only the log line, so the real question was whether it signals a fault, degrades support…

0votes
0comments
118views

Dell Force10 S4810 warns Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M on a third-party DAC

Monitoring reported packet loss toward an ESXi iSCSI host; on the Dell S4810 (FTOS 9.11(2.6)) the interface TenGigabitEthernet 0/37 showed the warning Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M because a non-Dell DAC was used. The link was up with normal traffic (about 16…

0votes
0comments
151views

Intel X710 in a Dell R740xd links with 2013 Cisco DACs (VID V02) but not 2019 ones (V03) of the same part number

Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the…

4votes
2comments
152views

Zyxel XGS4600 SFP+ modules randomly stop transmitting after firmware 4.50; DDM shows TX power -inf and 0 mA bias

On Zyxel XGS4600 switches, 10G and 1G SFP+ transceivers (including an FS.com DWDM-SFP10G-80) intermittently stopped transmitting; only removing and reinserting the module restored the link. Transceiver statistics at that moment showed TX power -inf dBm, voltage at the 3.00 V low alarm and TX bias…

France fiberwolf FR asked
1vote
2comments
79views

TP-Link T2600G-28TS SFP port shows UP but receives nothing over fibre to D-Link converters; firmware update fixed it

A T2600G-28TS (TL-SG3424) uplinked over fibre to another building using D-Link transceivers and media converters showed the SFP port UP and transmitting but never receiving packets. Restart, factory reset and other SFP ports were tried. Another user returned the switch after failing to link it to…

0votes
0comments
54views

Cisco-compatible CWDM SFPs that worked in PowerConnect 6024/6224 report transmit failure in an 8024F

Cisco-compatible CWDM SFP modules that had worked in Dell PowerConnect 6024 and 6224 switches produced a transmit failure error in a PowerConnect 8024F, presumably because the 8024F ports are SFP+. The poster considered Finisar FWLF1524P2Vxx modules but wanted confirmation from someone with a…