CodingBox Q&A Ask question

Brocade FC port in No_Sync: light is received but frames are out of sync, causes and the porterrshow delta method

Asked Active Viewed 35 Original language: English
3

switchshow on a Brocade FC switch lists a port as "16G No_Sync FC", portshow reports portState 2 Offline and portPhys 5 No_Sync, and sfpshow shws RX Power -7.0 dBm but TX Power -40.0 dBm. What dose No_Sync mean and how do I find which component is bad?

Comments 2

No_Sync means light is arrving but the receiver cannot synchronise to the incoming signal. A cablle fault or an SFP at either end can cause it; an offline port showing a disabled local laser is not sufficient evidence by itself.

2 Ukrainerxnode71UA Original (English)

After enabling the port, record or clear the counters, wait for a meaningful observation period and compare porterrshow deltas. Combine those changes with controlled cable and optic swaps instead of replacing whichever component happens to show the first alarm.

0 Ukrainenetguru15UA Original (English)
Log in to comment. Log in