switchshow on a Brocade FC switch lists a port as "16G No_Sync FC", portshow reports portState 2 Offline and portPhys 5 No_Sync, and sfpshow shws RX Power -7.0 dBm but TX Power -40.0 dBm. What dose No_Sync mean and how do I find which component is bad?
Comments 2
No_Syncmeans light is arrving but the receiver cannot synchronise to the incoming signal. A cablle fault or an SFP at either end can cause it; an offline port showing a disabled local laser is not sufficient evidence by itself.After enabling the port, record or clear the counters, wait for a meaningful observation period and compare
porterrshowdeltas. Combine those changes with controlled cable and optic swaps instead of replacing whichever component happens to show the first alarm.