All questions
Latest questions from the community.
I swapped the ISP ONU for an ODI DFP-34X-2C2 GPON stick in my Turris Omnia so the fibre terminates in the router instead of another box on the shelf. That part worked: the line is registered, traffic flows, no complaints. The problem is the rate. It never goes above 1Gbps, and 2.5G was the whole…
We run a three-node cluster with the nodes cabled directly to each other over 100G DAC, no switch in the path, and the interfaces put into a broadcast bond so replication traffic has its own fabric. Before I put real load on it I wanted a baseline, and the numbers do not agree with each other. 3x…
6votes
5comments
189views
Field turn-up work on SDH circuits, and the tester has been fighting me on the optical side lately. Same kit that has been fine for years, so before I book a service call I want a sanity check on the order I should be working through. Viavi T-BERD/MTS-5800 with the SFP port populated, generic…
3votes
4comments
302views
We are adding a G610 to an existing fabric and there is a box of non-Brocade 16G/32G FC SFP+ left over from another build. Before I plan any ports around them I put one into a spare port on the bench to see what the switch makes of it. Brocade G610, Gen 6 third-party 32G FC SFP+, no Brocade…
We hand over industrial cabinets with the customer's own monitoring on top, so readable DDMI on the uplink ports is part of the acceptance list. On an RGS200-12P the two ports that matter refuse to print anything at all after DDMI is enabled, even though both links are up and forwarding. Zyxel…
At home I've got Rostelecom fiber with the carrier's ONT installed, and I'd like to get the extra box out of the cabinet: plug an SFP ONU straight into the router and distribute it myself from there. I bought the stick, but I can't get past the first step. Keenetic Giga router, SFP port free Eltex…
Small office, one Firebox M470 on the perimeter, and I wanted to move the link to the core switch off copper and onto the built-in SFP+ ports. Bought a pair of generic SFP+ modules for it, one for each end. The switch side lights up straight away, the Firebox side never does. Kit: WatchGuard…
We run a handful of 80 km DWDM spans off EX4200s with third-party optics on both ends, because the vendor-branded DWDM parts were never going to fit the budget. That was fine for years. After the EX boxes were moved to Junos 12.3 the optics still sit in the same ports and the spans still exist, but…
6votes
6comments
209views
We run a small regional network and pulled a spare 7050T out of stock to use as a DWDM aggregation box. Arista-coded DWDM optics for it quote close to the price of the switch, so we bought third-party DWDM SFP+ instead, and now the switch will not talk to them. Arista 7050T, EOS 4.10.6 generic…
On an Aruba 1930 (JL685A, software 2.6.0) two D-NET DN-SFP-LX modules in SFP+ ports 49 and 50 actually carried traffic, yet the web dashboard showed both ports as DOWN and, without a CLI, the poster could not check whether the modules were identified. The question was whether this was a bug, an…
Moving my home FTTH line off the operator's ONT and onto a GPON stick in my own router, so that the fibre lands straight in the rack and I keep one box instead of two. The stick is recognised, the port comes up, and then nothing comes back. MikroTik CRS328-24P-4S+, stick in sfp-sfpplus1…
Several pairs of 3COM 2928 switches (JE007A-like, HP 1910-24G family) were linked over J9281B SFP+ DACs. After upgrading from 5.20 1108P01 to 5.20 1519P03 the links no longer came up. Before the update display transceiver interface showed STACKSFP / Tyco Electronics and simple LINK UPDOWN events…
The poster configured new HP 2530-48G switches (J9281B) with J9775A SFP+ direct-attach cables bought as accessories. The ports stayed down and the log said FFI: port 49 Transceiver type not supported in this port; show tech transceivers first showed nothing and, afer upgrading from YA.15.12.0007 to…
I picked up a couple of second-hand Arista switches for the lab and ran straight into the optics gate. Arista-coded modules link up, passive DAC cables link up, and anything third-party leaves the port down. The lab side: DCS-7150S-24, bought used, no support contract and no account team behind me…
A 2920-48G-PoE+ (J9729A) rejected a J9283B 3 m SFP+ DAC with 00536 FFI: port 45 Transceiver type not supported in this port even though HP lists the cable as compatible; the same cable worked in a 2530 with SFP+ slots. Firmware had been updated without effect. A later reader noticed an old J9283B…
We push traffic from a lab server into a CRS518-16XS-2XQ over a 100G QSFP28 uplink, and it leaves the switch through a MikroTik S+RJ10 copper SFP+ into a plain 1G RJ45 host. The receiving side is missing a large share of the packets and I cannot pin it on anything obvious. Setup: MikroTik…
3votes
4comments
170views
Running a CWDM ring at the access layer, Catalyst 3750 at aggregation. I got plain modules with no vendor encoding, case marking TTG965D1, 1470-1610 nm grid. The link comes up, traffic flows, but the switch treats them as SX modules: in both inventory and monitoring it shows SX instead of CWDM, so…
On an HP 5120-EI the poster inserted an Allied Telesis AT-SPEX 1310 nm SFP and got a PHONY ENTITY trap plus OPTMOD/4/FIBERSFPMODULENOWINVALID: This is not a supported transceiver for this platform; the port never came up. The poster looked for a command to disable enforcement of SFP coding. Later…
Homelab, nothing exotic. An Odroid H2 does routing duty on its 2.5GbE ports, and I wanted to hang it off one of the 10GbE SFP+ cages of the switch through an RJ45 copper module instead of pulling fibre across the room. QNAP QSW-M408S, copper module in one of the 10GbE SFP+ cages Odroid H2 router…
On an HPE 5510 24G SFP 4SFP+ HI (JH149A, Comware 7.1.045 R1111P01) genuien JD119B and JD118B 1G SFPs were accepted at first (OPTMOD/4/MODULEIN: The transceiver is 1000BASESXSFP), but after a cold power reboot the same modules were reported as UNKNOWNSFPPLUS with OPTMOD/5/CHKSUMERR: Transceiver…
Small office, two buildings, and all I want is a plaain 1000M fibre link between the racks. Both ends are configured for 1000M, both stay dark, and this has been dragging on for weeks now. TP-Link TL-SG3452P, hardware V3, firmware 3.20.4, link taken from one of its SFP cages PLANET IGS-6329-8UP2S4…
We poll a mixed fleet of ZTE ZXA10 OLTs from LibreNMS and two things are wrong. I suspect they are unrelated, but I am not sure. ZTE ZXA10 C300 on V2.1.0, still in service in an old POP ZTE ZXA10 C620 on V2.0.30, plus a C650 and a C650E one ZTE ZXA10 C320 that used to behave SFP and SFP+ uplinks…
We are collapsing two aggregation rows onto FortiSwitch, and the last piece is a 25G interconnect between an FS2048 and an FS648 in adjacent racks. Everything else in the design came up on the first attempt; this one link refuses to. FortiSwitch 2048, 25G front-panel port FortiSwitch 648, 25G…
Joining two campus buildings into one network. In building A there's an Avaya VSP 4400, and only 1G SFP ports are free there: the dedicated uplinks have long been taken for other purposes. In building B there's an Extreme Summit X690-48x-2q-4c, and there only 10G SFP+ ports are free, no other…
We are bringing up a pair of 8360-32Y4C as leaves and the downlink plan is deliberately mixed: mostly 25G to servers, a couple of 50G ports to a compute chassis, and a few slow copper drops for out-of-band gear. Because the SFP56 downlinks are grouped and the speed is set per group, I want to…
Small vSphere cluster, two 10G uplinks per host into a pair of top-of-rack switches. After the ToR was rebooted for a firmware update, part of the VMs on one host went silent and vMotion failed on both uplinks - yet ESXi never marked anything down and the adapter LEDs stayed lit the whole time…
An HP 5900AF-48XG-4QSFP+ (Comware 7.1.045 R2311P01) logged OPTMOD/4/PHONYMODULE: This is not a supported transceiver for this platform for two 10G SR SFP+ modules; display transceiver interface identified them as Avago and JDSU 10GBASESRSFP with DDM. The poster wanted to know which SFP+ to buy and…
The poster asked whether third-party optics can be used in an HPE FlexFabric 5700 40XG 2QSFP+ (JG896A) and whether the ProVision command allow-unsupported-transceiver exists on it. The answer clarified how Comware differs from ProVision: there is no allow-list of supported transceivers, so unlisted…
4votes
3comments
198views
Four HP A5500-HI switches in an IRF stack logged unsupported transceiver messages for six rear-module (JD368B) ports that were cabled with HP J9281B SFP+ DACs to ProLiant Gen8 servers with 530SFP+ NICs. display transceiver interface shwed Transceiver Type STACKSFPPLUS, Connector COPPER, Vendor Name…
5votes
4comments
202views
A link between two of our sites: about 27 km of single-mode fiber, MES3324F on both ends. Installed a pair of 1550 nm FANG HANG SFPs sold as 40-km modules. The link comes up, lives for a few dozen seconds, and drops, over and over, until the port gets blocked. 2 x Eltex MES3324F, firmware 4.0.7 SFP…