CodingBox Q&A Ask question

Which SFP28 DAC to use between an HPE 5950 and a Mellanox MCX4121A-ACAT

Asked Active Viewed 90 Original language: English
2

Before deployment the poster asked for a certified or tested SFP28 DAC to connect an HPE FlexFabric 5950 with an SFP28 card to a dual-port Mellanox MCX4121A-ACAT (ConnectX-4 Lx), and for any documentation of that pairing. Hardware involved: HPE FlexFabric 5950, Mellanox MCX4121A-ACAT, SFP28 DAC, 10Gtek MSA-compliant twinax.

  • Hardware: HPE FlexFabric 5950, Mellanox MCX4121A-ACAT
  • Transceivers: SFP28 DAC, 10Gtek MSA-compliant twinax
  • Form factor: SFP28, DAC

Symptoms / messages:

pre-deployment cable selection

Comments 2

Accepted answer

Mellanox support referred to the ConnectX-4 Lx firmware release notes for tested passive copper cables and SFP28 modules, and expected no issue with spec-compliant cables even though the HPE 5950 was not specifically tested; HPE's datasheet lists its own tested cables.

5 Chinacorebyte73CN Original (English)

A member suggested 10Gtek MSA-compliant twinax cables that work across HPE and Mellanox.

0 Italycoaxtech75IT Original (English)
Log in to comment. Log in