Several ConnectX-3 cards never light up optical transceivers but work with DACs

Asked Active Viewed 91 Original language: English
0

Mellanox ConnectX-3 MCX314A-BCBT and MCX354A-FCB cards (firmware 2.42.5000, driver 5.50.14740.1) were detected in Windows 11 and Ubuntu 22.10 but no optical transceiver ever emitted light: Cisco QSFP-40G-SR-BD, Cisco SFP-10G-SR and Mellanox MFM1T02A-SR were tried on LC-LC OM3, aross three motherboards, several PCIe slots and both IB and Ethernet port modes, with firmware reflashed. Copper DACs worked normally on the same cards.

  • Hardware: Mellanox ConnectX-3 MCX314A-BCBT, Mellanox ConnectX-3 MCX354A-FCB
  • Transceivers: Cisco QSFP-40G-SR-BD, Cisco SFP-10G-SR, Mellanox MFM1T02A-SR
  • Form factor: QSFP+, SFP+, DAC

Symptoms / messages:

no light from transceiver
no link light
DAC works, optics do not

Comments 1

Suggestions covered confirming the latest firmware, avoiding Cisco-locked optics in favour of Mellanox or generic ones, verifying Ethernet vs InfiniBand mode and testing DACs; the DAC test confirmed the cards worked, but optics never activated, possibly due to a per-port power limit (about 1.5 W) below what the optics needed.