CodingBox Q&A Ask question

Questions tagged “10gtek”

3 questions
15 30 50 per page
2votes
1 answer
96views

10Gtek ASF-10G-T copper module: ethtool -m returns Operation not supported until the NIC firmware is updated

A customer with a 10Gtek ASF-10G-T 10GBASE-T transceiver could not read its EEPROM: ethtool -m ens802f0 returned Cannot get module EEPROM information: Operation not supported. The vendor attributed it to a firmware version mismatch between the NIC and the transceiver. Hardware involved: 10G NIC…

1vote
1 answer
141views

10Gtek ASF-GE-T copper SFPs stop linking on a CRS309 after RouterOS 7.14 because of a wrongly programmed EEPROM

After upgrading a CRS309-1G-8S+IN from RouterOS 6.48.6 to 7.14.1 (and 7.15beta8), ports 5 and 7 with 10Gtek ASF-GE-T (FTRJ8519P1BNL-PT) copper SFPs showed sfp-rx-loss: yes and no-link when auto-negotiation was enabled; disabling auto-negotiation and forcing 1G full duplex restored the link…

2votes
2comments
119views

Intel 82599ES with 10Gtek DACs and transceivers: link flaps up and down on Linux and FreeBSD

Used Intel 82599ES 10-Gigabit SFI/SFP+ NICs from eBay were connected with 10Gtek SFP+ DACs and, via QNAP switches, with 10Gtek SR transceivers over OM3. On Linux dmesg looped NIC Link is Up 10 Gbps / NIC Link is Down; on FreeBSD the interface showed no carrier and DHCP failed. allowunsupportedsfp=1…