CodingBox Q&A Ask question

Questions tagged “freebsd”

5 questions
15 30 50 per page
2votes
1 answer
104views

OPNsense 22.7: interface is disabled due to unsupported sfp on a 10G port, and the Linux ixgbe tunable does not apply

After upgrading OPNsense from the 21.x series to 22.7 a 10G SFP+ port stopped working with interface is disabled due to unsupported sfp; the newer Intel driver actively disables unrecognised modules. The poster tried to set ixgbe.allowunsupportedsfp=1 as a system tunable, which was not accepted…

2votes
2comments
118views

Intel 82599ES with 10Gtek DACs and transceivers: link flaps up and down on Linux and FreeBSD

Used Intel 82599ES 10-Gigabit SFI/SFP+ NICs from eBay were connected with 10Gtek SFP+ DACs and, via QNAP switches, with 10Gtek SR transceivers over OM3. On Linux dmesg looped NIC Link is Up 10 Gbps / NIC Link is Down; on FreeBSD the interface showed no carrier and DHCP failed. allowunsupportedsfp=1…

3votes
1 answer
155views

Where to set hw.ix.unsupported_sfp=1 on a Netgate XG-7100 with third-party optics (loader.conf.local vs GUI tunables)

The poster had third-party SFP+ optics for both the on-board Intel X553 ports of a Netgate XG-7100 and an add-in X520-DA2 and had found that hw.ixgbe.unsupportedsfp=1 in /boot/loader.conf enables them. Questions: does it apply to both on-board and PCIe Intel ports, what is the difference between…