An embedded device with a 10GbE SFP transceiver kept logging power warnings above 800 mW and occasional errors when fed by an NVIDIA/Mellanox MMA2P00-AS 10/25G transceiver over a 2 m OM3 LC patch. The poster assumed transmit power is negotiated between the two ends and asked whether a failed…
Mellanox ConnectX-3 MCX314A-BCBT and MCX354A-FCB cards (firmware 2.42.5000, driver 5.50.14740.1) were detected in Windows 11 and Ubuntu 22.10 but no optical transceiver ever emitted light: Cisco QSFP-40G-SR-BD, Cisco SFP-10G-SR and Mellanox MFM1T02A-SR were tried on LC-LC OM3, aross three…
2votes
2comments
118views
Used Intel 82599ES 10-Gigabit SFI/SFP+ NICs from eBay were connected with 10Gtek SFP+ DACs and, via QNAP switches, with 10Gtek SR transceivers over OM3. On Linux dmesg looped NIC Link is Up 10 Gbps / NIC Link is Down; on FreeBSD the interface showed no carrier and DHCP failed. allowunsupportedsfp=1…
In a home lab with an Aruba S2500 PoE switch and an Intel X520-DA2, three of thirteen cheaply bought Intel AFBR-703SDZ-IN2 SFP+ modules (around 15 USD each) failed within three months: links dropped with dark activity LEDs, two on the switch side and one on the NIC side. Warm and cold reboots…
With two dual-port Mellanox ConnectX-4 cards, a MikroTik SFP+ switch, 1 m OM4 patches and mixed 10G/25G transceivers from several vendors, one NIC port showed link UP but got no DHCP and could not route, 25G transceivers negotiated only 1G, and previously stable 10G links dropped intermittently…
Before deployment the poster asked for a certified or tested SFP28 DAC to connect an HPE FlexFabric 5950 with an SFP28 card to a dual-port Mellanox MCX4121A-ACAT (ConnectX-4 Lx), and for any documentation of that pairing. Hardware involved: HPE FlexFabric 5950, Mellanox MCX4121A-ACAT, SFP28 DAC…
We are handing a 100G circuit off to a core router through a leased optical transport system, and the port on our side refuses to come up. The same pair of modules links instantly on the bench, which is what makes this so irritating. Wedge100BF-32X (wedge100bf32x) running SONiC InnoLight…
Intel-branded servers witth a built-in ConnectX-3 (MT27500, ConnectX3-A1-WSP-QDR, firmware 2.36.5000, mlx4en 4.6, kernel 4.19.68) lost link when a QSFP-to-SFP+ adapter with an SFP+ transceiver replaced direct QSFP cabling: ethtool reported Link detected: no and speed Unknown!, port in ETH moe. The…
Home setup, everything in one rack. I want to connect the NAS to the switch faster than gigabit, but I don't want to run fiber: the distance is about five meters, a plain patch cord covers it. D-Link DGS-1250-28X switch, SFP+ ports free TerraMaster F4-424 Max NAS, copper RJ-45 port short Cat6a…
Small homelab, two second-hand switches and a drawer of optics collected over the years, most of which the hosts refuse because of the vendor code. Recoding has always been the blocker: a proper programmer sits around 369 USD, which is more than I paid for the switches, and the Ubiquiti SFP Wizard…
I do industrial installs, mostly Hirschmann switches in cabinets nobody wants to open twice. On the last couple of projects the optics were the line item that hurt: the switches expect Hirschmann-coded modules, and the original M-SFP parts cost several times an equivalent generic module, with lead…
The poster wanted to use a QSFP+ 40G-to-4x10G breakout cable on a two-port Mellanox ConnectX-3 Pro (MT27520, firmware 2.42.5044, PSID HP1370110017, MLNX OFED 4.6 on Debian 9.6) so each 10G leg could connect to a different switch, similar to what an Intel XL710 offers. SR-IOV virtual functions had…
On Debian 8.11 (kernel 3.16) the poster ran ethtool -m on a Mellanox MT26448 adapter to read optical diagnostics (TX/RX power, temperature, voltage, thresholds) and got Cannot get module EEPROM information: Input/output error. Hardware involved: Mellanox MT26448 ConnectX-2, SFP+ optic with DDM…
I want the ISP box out of the meter cupboard and the GPON line terminated straight on the router. It is a KPN-based line, fibre comes in on SC/APC, and the idea is to move the WAN from the Huawei ONT into the SFP+ cage of the UDM-Pro and keep exactly the VLAN 6 / PPPoE setup the ONT was running…
A DGX Spark with a ConnectX-7 NIC was connected to an existing 10G SFP+ optical network through an inexpensive QSFP-to-SFP+ adapter bought on AliExpress; neither DACs nor standard optical modules produced any link. The poster asked whether the setup could work at all and how to configure it…
2votes
2comments
120views
We are moving the office uplinks from copper to fibre and the quote that came back has DrayTek-branded optics in every line. Before I start arguing about the difference against ordinary 10G modules I would like to know whether the hardware actually cares what sits in the cage, because the…
2votes
2comments
112views
I do small business installs, and this one is a fibre service handed off on an ADVA FSP 150-GE102Pro. The customer wants the WAN terminated on their own router instead of the carrier box, so it has to land in the SFP+ cage of a MikroTik RB4011iGS+. Nobody told me what fibre the service actually…
A QSFP112 400G SR4 module in a ConnectX-7 (MCX755106AC-HEAT) with an MPO-12 Type-B cable showed module state Ready and data path DPActivated, but mlxlink --showmodule reported State = Disable, Supported Cable Speed = 0x00000000, Compliance = Unspecified/Undefined, Power Class 1.5 W (too low for…
0votes
0comments
118views
We are wiring an FPGA capture card into an existing server and I am stuck at the very first step: the port simply never comes up. The setup: Mellanox MCX414-GCAT (ConnectX-4 EN, QSFP28, 50GbE capable) in the host FS Q-8LCA020 breakout AOC, QSFP+ on one end, eight LC ends on the other FPGA card on…
Standing up 25G uplinks from a QFX5120-48Y towards a second switch and a couple of new servers. Before I hand the segment over I want the link settings written down properly, and I cannot find where auto-negotiation lives on these ports. Juniper QFX5120-48Y 25G optics in the SFP28 cages et…
We are refreshing the core of a small office and put in a pair of Aruba CX 6200F. The link between the two switches is meant to be a 10G trunk on the SFP+ uplinks, and I cannot get either box to admit that 10G exists on that port. 2x Aruba CX 6200F Switch Series, trunk on port 1/1/25 Cisco…
A good half of my work is putting one company's optics into another company's switch, so I spend a lot of time asking a module what it thinks it is. My toolbox for that is currently one command deep, and I would like to know what else is worth putting on the bench machine. Linux boxes with SFP+ and…
Small office, we are dropping the ISP-supplied box and terminating the fibre straight on the router. The handoff is AON, the provider only asks for a VLAN tag, no PPPoE and no ONT registration. What is in the rack: TP-Link ER7412-M2 V1, firmware 1.0.1, fibre into port 11 (SFP WAN) a TP-Link…
3votes
3comments
113views
We are pushing Wi-Fi into an outbuilding on a campus site. The only fibre going that way is a single strand, so the plan was to hang an AP-375 out there and feed it over a BiDi pair we already had on the shelf. Aruba AP-375, ArubaOS 8 Cisco BiDi SFP in the AP cage, its matching partner wavelength…
A dual-port ConnectX-5 (MT27800, firmware 16.35.1012, MLNXOFED 5.8 on BC-Linux 8.2) connected to a switch with a DAC would not recover after the cable had been connected and disconnected about fifteen times: the port stayed in State: Polling with Physical state ETHANFSMABILITYDETECT, and mlxlink…
On a Mellanox SN2410 (MLNX-OS 3.6.4112) a 100G port connected to a Chelsio adapter through a 2 m unequalised QSFP copper cable would not link when FEC was disabled; no HSS lane signal was detected on the adapter side. The poster required FEC-off operaation and asked whether the switch supports it…
I look after a two-building site and the access switches were replaced with Aruba 2540s a while back. The fibre between the buildings has not been touched, but since the swap the uplink refuses to come up. Aruba 2540 on our side, ports 51 and 52 used for the uplinks Aruba J4858D 1000SX in the 2540…
Mellanox-branded Q-4S28AO03 3 m QSFP28 AOC 1x4 breakout cables (100G with FEC) that worked under Onyx 3.9.1908 stopped linking after an upgrade to Onyx 3.10.x. The ports reported Cable speed not enabled and, with auto speed, Negotiation failure; supported speeds showed 1G/10G/25G but the actual…
A Synology RS3614xs+ with a supported Intel X520-DA2 rejected the wrongly ordered SFP+ modules as unsupported. Putting options ixgbe allowunsupportedsfp=1 into /etc/modules.conf had no effcet, and even when the kernel log showed ixgbe: allowunsupportedsfp Enabled the driver still reported failed to…
Adding a 100G link between two racks on an X690 that has been quietly doing 10G access work for a couple of years. The uplink cage will not take the speed at all. ExtremeSwitching X690-48x-2q-4c 1 m QSFP28 direct attach cable, Q28+CR41m port 57, one of the QSFP28 uplink cages The cable comes up as…
4votes
2comments
107views
A site decommission left me with a drawer of pulled Cisco optics, a mix of GBICs, 1G SFPs and 10G SFP+, and I have to decide which of them go back into production and which go in the bin. The GBICs I have put aside for now, since nothing on the bench takes them, so everything below is about the SFP…
A Mellanox ConnectX-4 Lx (MCX4121A-ACAAx, firmware 14.32.1900) in a Ryzen desktop (Fedora 41 and Windows 10) detected the interface but reported Cable is unplugged with two FS.com SFP28-25GLR-31 modules and a 40 m single-mode LC duplex patch; a MikroTik router recognised the same optics. The poster…
A Mellanox ConnectX-3 40GbE NIC connected with Mellanox QSFP passive copper cables (MC2210126-005) to a Dell PowerConnect 8164 (firmware 5.1.4.5) produced a link-up event for a few seconds followed by a permanent link-down. The same cables worked NIC-to-NIC, and Dell refused support because the…
5votes
3comments
129views
We run a couple of IBM Power boxes next to a small SAN, and I am trying to write down a sane spares policy before the next hardware maintenance renewal. The part I cannot pin down is the transceiver itself: on some adapters it looks like a field-replaceable part in its own right, on others a…
Bringing up a 10G uplink from a PA-3220 to a new core switch. The module went into a free cage on the firewall, the switch side is configured and waiting, and the interface simply refuses to come up. The port LED blinks, which is what made me assume the module was at least being powered. Palo Alto…
Standing up a small traffic-test bench next to the production fabric, and the tester ports will not come up over copper at all. HP 5900 40G switch, JC772A HP JG328A 40G QSFP+ direct attach cable Ixia Xcellon-Multis QSFP 40/10GE load module Spirent TestCenter 40G module, tried as a second opinion HP…
Putting a fibre run between two comms rooms in the same building and using a pair of TRENDnet TFC-1000MSC converters (1000BASE-T to 1000BASE-SX) to bridge it. Copper side goes straight into the switches we already have, nothing unusual in the config. TRENDnet TFC-1000MSC at each end, each on its…
5votes
4comments
160views
Bench work: re-coding a small batch of SFP+ modules so they carry the vendor string and part number the customer's kit expects. The edit itself is trivial in a hex editor, the write goes through, the read back matches byte for byte what I wrote - and the host still throws the module out. generic…
Installing a new MES2324FB at a site to replace old hardware. The uplink is 1G fiber to an Alcatel 6224, Foxgate modules from the same batch as at neighboring sites. Setup: Eltex MES2324FB, firmware 4.0.4.7, also tried 4.0.6 - no difference 1G SFP Foxgate on both ends of the link far end - Alcatel…
I look after the access layer at a small ISP and I want our two GPON OLTs to show up in monitoring the same way everything else does. The wish list is not exotic: how hot the chassis runs, CPU and RAM load, counters per port, and the part I actually caare about, the optical side. That means Rx/Tx…
I look after a small office network and put in a DrayTek VigorSwitch FX2120 to get a 10G core. Both 10G links, to the router and to the NAS, came up on their own within seconds. What I cannot do is get a single 1G device onto the switch through the SFP+ cages. Switch: DrayTek VigorSwitch FX2120…
We are a small regional ISP rebuilding the optics budget for next year. Every 10G spare on our shelf is coded for exactly one platform, so the spares pool is roughly three times larger than our failure rate justifies. The idea on the table is to buy re-codable modules and code them ourselves as…
Replacing a customer's incumbent aggregation pair with CloudEngine kit, and the single link that refuses to come up is the 100GE feed into their packet broker. Everything else on the switch went in without drama. Huawei CloudEngine 6800, 100GE port 100GBASE-SR4 QSFP28 modules, Huawei parts, one at…
Commissioning a 10G handoff for a customer on a 3930 that was already on site. The module is Ciena's own, pulled from our stock, and the port does come up - but the operational state is UCTF instead of Ena and the uncertified transceiver alarm sits there permanently. The acceptance test includes a…
A Linux server with an Intel 82599ES 10-Gigabit SFI/SFP+ controller showed no 10G interface and dmesg contained failed to load because an unsupported SFP+ or QSFP module type was detected after an untested SFP+ module was inserted. The article explains that the ixgbe driver only enables modules it…
I am putting together a switchless Fibre Channel setup at home: one box holds the storage and has to act as the FC target, the other two are plain initiaators. No FC switch in the middle, just direct cables between HBAs. Hardware: QLogic QLE2694 in the storage box, the one that should be the target…
All 10G ports on a Netgear M5300-28G3 were used, so the poster asked whether a Cisco 3 m SFP+ DAC (H10GB-CU3M) or Finisar FTLX8571D3BCL 10G SR modules could be used in the switch's 1G SFP ports to add another 10G-capable device at reduced speed. Hardware involved: Netgear M5300-28G3, Cisco…
A Dell-branded Intel X520-DA2 with Flypro 10GBASE-T SFP+ modules showed no carrier (or no interface at all) on Debian and on FreeBSD-based OPNsense because the card rejects unapproved modules. The post collects the per-OS fixes and the permanent EEPROM approach. Hardware involved: Dell-branded…
Homelab switch: a D-Link DGS-1210-28 revision F1 that I flashed with OpenWrt so I could stop fighting the stock web UI. Everything works except the last four ports, which are the copper/fibre combo ones. Switch: D-Link DGS-1210-28 rev F1 Firmware: OpenWrt 21.02.0-rc3 (r16172-2aba3e9784) Ports…
The poster bought a Cisco SFP-10G-SR on eBay (markings suggesting 2007 manufacture) and, warned about counterfeit Cisco optics with longevity and safety risks, asked how to tell whether it was genuine before deploying it. Hardware involved: Cisco SFP-10G-SR. Reported symptoms/messages: authenticity…