New MikroTik hEX S (2025) will not link with a Nokia G-010S-A/G-010S-P GPON stick until speed is forced and the router is power-cycled
Asked Active Viewed 26 Original language: English
3
A Nokia G-010S-A GPON stick that worked for two years in an older hEX S gives no link and no partner advertising in the 2025 hEX S (E60UiGS); RX jabber frames are counted and PPPoE never comes up. Is the module or the router at fault?
The reported hEX S issue involved the module-initialisation path. The workaround fixed the port at auto-negotiation=no speed=1G-baseX, followed by a power cycle or reseat and time for the ONU to initialise.
Applying the rate alone was insufficient in that case. Check the exact hEX S revision and RouterOS fix notes; a GPON stick working in the older hardware does not establish identical EEPROM/I2C behaviour on the replacement router.
Comments 2
The reported hEX S issue involved the module-initialisation path. The workaround fixed the port at
auto-negotiation=no speed=1G-baseX, followed by a power cycle or reseat and time for the ONU to initialise.Applying the rate alone was insufficient in that case. Check the exact hEX S revision and RouterOS fix notes; a GPON stick working in the older hardware does not establish identical EEPROM/I2C behaviour on the replacement router.