Four clients only have 1G RJ45 interfaces. Can an SN2410 (or the smaller SN2140) take 1000BASE-T SFP modules or 10GBASE-T SFP+ modules in its SFP28 ports?

Comments 2

Check the per-port power allowance as well as BASE-T module support. The referenced SN2410 guidance permits up to 2.5 W on ports 1, 2, 47 and 48, with a lower allowance on the other SFP ports.

4 Spainrxadmin25ES Original (English)

Keep that allocation tied to the actual model's documentation; it is not a rule for every Spectrum switch. No result for the asker's proposed module was reported, so the power table should guide selection rather than be treated as a completed interoperability test.

0 Türkiyedwdmops44TR Original (English)