Transceiver compatibility
Vendor locks, unsupported module errors, matching modules to switches, NICs and routers
Newly delivered EdgeSwitch ES-24 units linked to each other over gigabit SX SFPs, but the same modules (HP J4858B, J4858A, Avago AFBR-57M5APZ, Avaya AFBR5715PZ, Cisco) would not link ES-24 to HP ProCurve (four models) or Netgear (two models): the ES-24 showed a link light, the other side did not…
0votes
0comments
172views
With a CSS326-24G-2S+ (SwOS 2.6) and a server with an Intel 82599 card, two different S+DA0001 DACs and two Intel cards never linked; two CSS326 switches connected by DAC only achieved 1 Gbps. A later reader on SwOS 2.12 with an 82599 reported the same. No solution was posted. Hardware involved…
After upgrading a CRS309-1G-8S+IN from RouterOS 6.48.6 to 7.14.1 (and 7.15beta8), ports 5 and 7 with 10Gtek ASF-GE-T (FTRJ8519P1BNL-PT) copper SFPs showed sfp-rx-loss: yes and no-link when auto-negotiation was enabled; disabling auto-negotiation and forcing 1G full duplex restored the link…
A user with a MikroTik GPON ONU SFP module in a RouterBOARD facing a FiberLink OLT saw the interface as registered but the module serial never appeared in the OLT for provisioning. The thread turned into a reliability report: an operator lost every deployed MikroTik GPON module within two months of…
With auto-negotiation on, CRS317 and CRS326 SFP+ interfaces ran at 10G; with auto-negotiation=no, speed=10Gbps and full-duplex=yes the log still reported link up (speed 1G, full duplex) regardless of the advertise settings. On a CCR1009 the same configuration produced no-link instead, showing that…
A MikroTik CRS312-4C+8XG (RouterOS 7.13.4) and a Ubiquiti USW-Pro-48 (6.6.61) over 20 m OM3 with SR 850 nm SFP+ optics would only negotiate 1G full duplex; 10G attempts failed with no link and occasional Rx Fault on the UniFi side. Several fibre and transceiver combinations were tested and RouterOS…
Contradicting MikroTik's documented advice to force 1G full duplex when using 1G optics in SFP+ ports, a Netpower Lite 7R linked to an RBFTC11 only with auto-negotiation (forced 1G gave link up but zero received packets), while the same Netpower to a CRS328-4C-20S-4S+ had heavy packet loss and FCS…
Replacing the ISP ONU with a Baudcom DB-1234-SFM GPON SFP stick in a hEX S: the stick registered with the OLT and obtained an IP with the spoofed MAC, but with sfp1 as WAN pings returned network unreachable, although the same configuration on ether1 (behind the ISP ONU) worked and Winbox showed no…
Two Solid Optics SFP-H25GB-CU5M SFP28 DACs between a MikroTik CCR2004-1G-12S+2XS and an FS S5860-20SQ switch produced status: no-link on sfp28-1 and sfp28-2 with auto-negotiation off, 25 Gbps, full duplex, FEC91 and no flow control; RouterOS 7.8rc1 was tried on vendor advice. The modules were…
A MikroTik CSS610-8G-2S+IN showed an active SFP+ link, but Intel X520-DA1/DA2 NICs (Windows, Linux, ESXi) reported no link, reproducibly across multiple transceiver pairs, DACs and two cards. Firmware 2.12, 2.13rc6, 2.13rc12, 2.13rc25 and the final 2.13 were tested. Hardware involved: MikroTik…
A CRS326-24G-2S+RM and a CCR1009-7G-1C-1S+PC connected with a MikroTik SplusDA0001 SFP+ DAC only linked at 1 Gbps; enabling 10G dropped the link, and the CRS326 in SwOS did not even offer a 10G option. The poster needed SwOS for harrdware LACP. RouterOS/SwOS updates, supout files, and a replacement…
A CSS326 (SwOS 2.12) uplinked to an RB4011 throuhg an FS.com 10G active DAC accumulated Rx MAC errors, Rx FCS errors and Tx pauses. Cleaning the DAC connectosr did not help, and the poster asked whether SwOS had SFP+ bugs. Hardware involved: MikroTik CSS326-24G-2S+, MikroTik RB4011, FS.com 10G…
The poster wanted to use a MikroTik XS+DA0001 passive DAC between the 1G SFP port of an RB3011 and an SFP+ port of a CRS309 and asked whether a passive cable can bridge different SFP generations. The RB3011 SFP cage is 1G only while the CRS309 cage is SFP+ (10G), and a passive DAC has no active…
A FLYPRO SFP-1G-CS-100M 1000BASE-T module in a MikroTik CRS112-8P-4S (RouterOS 6.47.10) was detected but reported no-link with sfp-rx-loss: yes, whatever the far end (MikroTik LHG/RB750Gr3, Ubiquiti, Cisco). Fixed 1G speeds, other module units and rebootts were tried; only a Ubiquiti switch linked…
SFP+ DACs linked MikroTik-to-MikroTik and OLT-to-OLT, but between a V-SOL EPON OLT 16008D and a CCR2004-1G-12S+2XS or CRS326-24G-2S+RM the OLT reported the interface as disconnected. The same DACs were recognised on both platforms, so the poster suspected a cross-vendor auto-negotiation or…
On a CRS226-24G-S2+RM (RouterOS 6.42.11 long-term) the SFP+ port stayed at no link, not running, slave after a power loss, while software reboots were fine; disabling and re-enabling the interface fixed it manually. The problematic module was a Huawei MA5671A GPON SFP, other SFPs behaved, and the…
4votes
3comments
115views
After upgrading a CRS305-1G-4S+ to SwOS 2.12, SFP-GE-T 1000BASE-T copper SFPs stopped linking although the switch still identified them in the SFP tab; the same modules kept working on a CRS317-1G-16S+ with the same firmware. Modules inserted before the upgrade continued to work, modules inserted…
On a CRS326-24G-2S+ with RouterOS 7.7 three third-party 1G RJ45 SFPs failed: an HP 453156-001 (FCLF-8521-3-HP) showed no-link with auto-negotiation: failed, a Foundry E1MG-TX showed no-link with sfp-rx-loss: yes even with manual speed, and a Ubiquiti UF-RJ45-1G also stayed at no-link. Hardware…
A MikroTik CCR1036-8G-2S+ with S-31DLC20D 1.25G single-mode SFPs reported link OK but no traffic flowed; TX power was blank and RX was -9 dBm. The identical module on the same fibre worked in a CCR1036-12G-4S. Port disable/enable, forcing 1G full duplex on both ends and support tickets did not…
Two FS.com 1G BiDi SFPs (1490/1310 and 1310/1490 nm) in a MikroTik CRS326-24G-2S+ running SwOS 2.9 detected incoming light around -6 dBm but never established a link; the same optics linked on a Netgear switch. The poster asked whether a manual speed setting was needed and whether RouterOS would…
A first-time SFP+ deployment between a UniFi 16XG switch and a Tehuti Networks TN9310 SFP+ adapter, with transceivers the reseller called compatible, produced an Rx fault indication in the UniFi controller. Swapping the fibre ends (polarity) did not help. Hardware involved: Ubiquiti US-16-XG…
FS.com 40 km 1550 nm SFP+ modules (item 11592) showed their information in a MikroTik CCR1016 but never linked in the SFP+ ports, whatever the auto-negotiation, 1G/10G speed or flow-control settings; standard 10G modules (item 29851) worked in the same ports, and the 40 km modules ran at 1G in…
A MikroTik CSS610-8P-2S+ (SwOS Lite) needed to connect its SFP+ ports to a Cisco Nexus 5596UP. The ports showed the transceivers in the web UI but no link, after trying several fibre cables and transceivers. The switch web UI listed vendor and type for each module, yet the port stayed at no-link…
With two dual-port Mellanox ConnectX-4 cards, a MikroTik SFP+ switch, 1 m OM4 patches and mixed 10G/25G transceivers from several vendors, one NIC port showed link UP but got no DHCP and could not route, 25G transceivers negotiated only 1G, and previously stable 10G links dropped intermittently…
Home setup, everything in one rack. I want to connect the NAS to the switch faster than gigabit, but I don't want to run fiber: the distance is about five meters, a plain patch cord covers it. D-Link DGS-1250-28X switch, SFP+ ports free TerraMaster F4-424 Max NAS, copper RJ-45 port short Cat6a…
Small homelab, two second-hand switches and a drawer of optics collected over the years, most of which the hosts refuse because of the vendor code. Recoding has always been the blocker: a proper programmer sits around 369 USD, which is more than I paid for the switches, and the Ubiquiti SFP Wizard…
I want the ISP box out of the meter cupboard and the GPON line terminated straight on the router. It is a KPN-based line, fibre comes in on SC/APC, and the idea is to move the WAN from the Huawei ONT into the SFP+ cage of the UDM-Pro and keep exactly the VLAN 6 / PPPoE setup the ONT was running…
2votes
2comments
120views
We are moving the office uplinks from copper to fibre and the quote that came back has DrayTek-branded optics in every line. Before I start arguing about the difference against ordinary 10G modules I would like to know whether the hardware actually cares what sits in the cage, because the…
2votes
2comments
112views
I do small business installs, and this one is a fibre service handed off on an ADVA FSP 150-GE102Pro. The customer wants the WAN terminated on their own router instead of the carrier box, so it has to land in the SFP+ cage of a MikroTik RB4011iGS+. Nobody told me what fibre the service actually…
Standing up 25G uplinks from a QFX5120-48Y towards a second switch and a couple of new servers. Before I hand the segment over I want the link settings written down properly, and I cannot find where auto-negotiation lives on these ports. Juniper QFX5120-48Y 25G optics in the SFP28 cages et…