QFX5200: FEC91 (RS-FEC) cannot be enabled on 4x25G breakout ports, IBM z OSA link fails

Asked Active Viewed 55 Original language: English
1

A QFX5200 100G port was channelized with a breakout cable into 4x25G (et-0/0/18:0 to :3) to connect an IBM System z OSA adapter. The configuration uses gigether-options fec fec91 and the commit succeeded, but the interface still reports Ethernet FEC Mode: FEC74 and the mainframe side logs error 2E432104 because it requires RS-FEC. IEEE 802.3by and Juniper's own documents say 25G uses Clause 91 RS-FEC, so why does the switch stay on FEC74?

Comments 2

The reported QFX5200 4x25G limitation is in the PFE capability: the CLI accepts the FEC91 setting while the operational hardware remains at FEC74. A successful commit is not proof that RS-FEC is active.

3 United Statestxnode67US Original (English)

Check the operational FEC and the peer's actual requirements. If the IBM adapter requires RS-FEC and cannot use a mutually supported alternative, another compatible port/platform is needed; repeating the same FEC91 command cannot add the missing hardware support.