Z9332F SONiC: after dynamic port breakout, show interfaces status shows media type N/A and TRANSCEIVER_INFO is empty
On a DellEMC Z9332f-O32 running SONiC master with the affected dynamic-breakout implementation a 400G port is broken out with config interface breakout Ethernet0 4x100G. Afterwards shhow interfaces status prints N/A in the Type column for the new sub-ports (Ethernet2, Ethernet4 ...) insteda of the expected QSFP-DD description, and querying STATE_DB for TRANSCEIVER_INFO of those ports returns nothing. Why does the transceiver information disappear after breakout?
Comments 2
The analysed SONiC issue involved a race between xcvrd tasks while logical ports were being recreated. The CMIS manager could access the state table before the port-change handler had populated the new interfaces.
Inspect xcvrd exceptions and the insatlled fix history rather than treating an empty TRANSCEIVER_INFO record as proof that the optic is absent. The proposed corrections coordinated the task order and logical-port creation; this record does not establish a universally fixed package version.