A home-lab Aruba 2930F should link at 10G to a Ubiquiti UDM-Pro using Ubiquiti's own SFP+ SR modules. The Ubiquiti end is fine, but the Aruba port flags the module as unsupported and stays dark. How does one make the 2930F accept it?

Comments 2

The reported 2930F setup used allow-unsupported-transceiver, confirmation, write memory and a reboot. On an Aruba Central-managed switch, the procedure first required the documented support-mode access.

1 RussiawaveadminRU Original (English)

Verify the module and link after the reboot and restore the intended Central management mode. Treat this as the reported unsupported-optics procedure for that platform, not a general warranty or qualification promise.