Ubiquiti UACC-OM-SM-10G-S-2 and UACC-CM-RJ45-1G in a MikroTik CRS326-24S+2Q+RM
Asked Active Viewed 16 Original language: English
1
Only Ubiquiti optics (UACC-OM-SM-10G-S-2) are easy to buy locally. Will they work in a MikroTik CRS326-24S+2Q+RM, and does MikroTik restrict third-party modules?
Working operation was reported for UACC-OM-SM-10G-S-2 optics in the specified CRS326. That supports the exact combination rather than a claim that all Ubiquiti modules behave alike.
The copper UACC-CM-RJ45-1G example needed separate settings: negotiation off, a fixed 1G BaseT full-duplex rate and a port disable/enable. Keep the optical and copper cases separate when reproducing the configuration.
Comments 2
Working operation was reported for UACC-OM-SM-10G-S-2 optics in the specified CRS326. That supports the exact combination rather than a claim that all Ubiquiti modules behave alike.
The copper UACC-CM-RJ45-1G example needed separate settings: negotiation off, a fixed 1G BaseT full-duplex rate and a port disable/enable. Keep the optical and copper cases separate when reproducing the configuration.