Intel E810-CQDA2 to MikroTik CRS520 over an FS QSFP28 AOC: no link until autonegotiation is disabled

Asked Active Viewed 51 Original language: English
3

A homelab user connected an Intel E810-CQDA2 100G adapter (ice driver 2.2.9, NVM 4.80 0x80020543) to a MikroTik CRS520-4XS-16XQ-RM using an FS QSFP28 active optical cable coded as Intel-compatible. Linux sees the NIC, but no link forms: the switch port shows it is transmitting while receiving nothing. What is wrong with the AOC or the settings?

Comments 2

The confirmed CRS520 setting disabled autonegotiation and forced the port to the supported 100G base-r4/lr4 mode. FEC was left on automatic in that specific working setup.

3 Egyptedgewolf25EG Original (English)

Earlier FEC suggstions were not the confirmed fix. Compare the actual switch-side speed and negotiation settings witth the E810 before replacing the AOC or declaring that FEC must always be forced on this pairing.

4 Ukrainerxnode71UA Original (English)