CodingBox Q&A Ask question

Top questions

Popular discussions about programming, compatibility and testing of optical transceivers.

354 questions
15 30 50 per page
0votes
1comment
68views

ONLP onlp_sfp_eeprom_read shifts QSFP EEPROM data on an Accton Wedge100BF (every other byte dropped)

On an Accton Wedge100BF-32x the ONLP call onlpsfpeepromread returned QSFP EEPROM data with alternating bytes skipped, so vendor strings appeared with every other symbol missing; the same transceiver read correctly on an Accton AS7312-54x. The vendor name FINISAR CORP appeared at the wrong offset…

0votes
1comment
30views

1G optics in MikroTik SFP+ ports: forced 1G fails to an RBFTC11 while auto-negotiation causes FCS errors to a CRS328

Contradicting MikroTik's documented advice to force 1G full duplex when using 1G optics in SFP+ ports, a Netpower Lite 7R linked to an RBFTC11 only with auto-negotiation (forced 1G gave link up but zero received packets), while the same Netpower to a CRS328-4C-20S-4S+ had heavy packet loss and FCS…

0votes
1comment
85views

SFP Access Port: RP2040-based open hardware to read and write SFP/SFP+ embedded EEPROM over USB

An open hardware/firmware project to read and write the EEPROM inside SFP and SFP+ modules so their capailities and vendor origin can be inspected and modified. It uses an RP2040 microcontroller and exposes a USB Mass Storage interface. The project is a work in progress and does not yet document…

0votes
0comments
118views

Dell Force10 S4810 warns Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M on a third-party DAC

Monitoring reported packet loss toward an ESXi iSCSI host; on the Dell S4810 (FTOS 9.11(2.6)) the interface TenGigabitEthernet 0/37 showed the warning Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M because a non-Dell DAC was used. The link was up with normal traffic (about 16…

0votes
1comment
63views

Genuine versus third-party SFP/SFP+ on Extreme switches: DDMI not readable on an X620, no vendor support

The poster had free thrid-party SFP/SFP+ samples that worked on Extreme switches and asked whether to buy genuine or third-party modules. A respondent reported that on a new X620 a third-party SFP+ linked but its DDMI data could not be read, and that Extreme provides no help for problems involving…

0votes
1comment
237views

ConnectX-4 Lx reports Cable is unplugged with FS.com SFP28-25GLR-31 modules over 40 m OS2

A Mellanox ConnectX-4 Lx (MCX4121A-ACAAx, firmware 14.32.1900) in a Ryzen desktop (Fedora 41 and Windows 10) detected the interface but reported Cable is unplugged with two FS.com SFP28-25GLR-31 modules and a 40 m single-mode LC duplex patch; a MikroTik router recognised the same optics. The poster…

0votes
0comments
151views

Intel X710 in a Dell R740xd links with 2013 Cisco DACs (VID V02) but not 2019 ones (V03) of the same part number

Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the…

0votes
0comments
54views

Cisco-compatible CWDM SFPs that worked in PowerConnect 6024/6224 report transmit failure in an 8024F

Cisco-compatible CWDM SFP modules that had worked in Dell PowerConnect 6024 and 6224 switches produced a transmit failure error in a PowerConnect 8024F, presumably because the 8024F ports are SFP+. The poster considered Finisar FWLF1524P2Vxx modules but wanted confirmation from someone with a…

0votes
0comments
109views

Dell S5212F-ON to Cisco C9500-48Y4C: dual-coded FS SFP28 DACs stay protocol down while 2 m Cisco/Cisco cables link

Between VxRail Dell S5212F-ON TOR switches and Cisco C9500-48Y4C switches, FS.com SFP28 DACs behaved inconsistently: a 5 m cable custom-coded Cisco on one end and Dell on the other came Line Up, Protocol down; a 2 m Cisco/Cisco-coded cable linked; a 3 m cable would not link even with the 2 m…

0votes
0comments
172views

CSS326-24G-2S+ and Intel 82599 NIC fail to link over an S+DA0001 DAC; switch-to-switch DAC only reaches 1G

With a CSS326-24G-2S+ (SwOS 2.6) and a server with an Intel 82599 card, two different S+DA0001 DACs and two Intel cards never linked; two CSS326 switches connected by DAC only achieved 1 Gbps. A later reader on SwOS 2.12 with an 82599 reported the same. No solution was posted. Hardware involved…

0votes
0comments
4views

Are you gonna add support for OSFP-XD ?

Hi, I am looking for a solution for working with OSFP-XD 1.6 (and higher) transceivers. Your documentation states that CodingBox supports various hardware programmer solutions. Are there plans to develop a programmer for the XD format, and if so, what is the estimated timeframe for the…

Singapore parallax SG asked
0votes
0comments
82views

Wedge100BF-32X on SONiC: 100G LR4 links back to back but not through the transport unless TX is patched first

We are handing a 100G circuit off to a core router through a leased optical transport system, and the port on our side refuses to come up. The same pair of modules links instantly on the bench, which is what makes this so irritating. Wedge100BF-32X (wedge100bf32x) running SONiC InnoLight…