1vote
1 answer
66views

How the SFP Wizard unlocks modules (part-number database plus brute force) and why not to downgrade the firmware

Reverse-engineering notes on the SFP Wizard: it reads a module's part number (page A0h bytes 40-55), looks it up in an embedded password database and sends the matching unlock password, falling back to brute force when unmatched. It traces the firmware evolution: v1.0.5 tried only the first…

0votes
0comments
174views

CSS326-24G-2S+ and Intel 82599 NIC fail to link over an S+DA0001 DAC; switch-to-switch DAC only reaches 1G

With a CSS326-24G-2S+ (SwOS 2.6) and a server with an Intel 82599 card, two different S+DA0001 DACs and two Intel cards never linked; two CSS326 switches connected by DAC only achieved 1 Gbps. A later reader on SwOS 2.12 with an 82599 reported the same. No solution was posted. Hardware involved…

3votes
3comments
109views

ethtool -m fails on FS.com XXV710 NIC: "Module EEPROM memory read not supported" and NVM not updatable

On Ubuntu 18.04 (kernel 5.4.0, ethtool 5.3, i40e 2.8.20-k) the poster used 25G XXV710-based NICs bought from FS.com (FS part XXV710AM2-F2, Intel XXV710 chipset). Link and error-free wire-speed traffic worked, but reading a transceiver's DMI data with sudo ethtool -m enp4s0f0 failed with "Cannot get…