CodingBox Q&A Ask question

QSFP-40G-SR-BD BiDi optics not detected on Nexus N9K-C93180YC-FX while QSFP-40GE-LR4 works

Asked Active Viewed 20
3

On a Cisco Nexus N9K-C93180YC-FX, QSFP-40G-SR-BD BiDi modules are not detected at all: nothing appears in the logs when they are inserted and they are absent from 'show interface transceiver', whereas QSFP-40GE-LR4 modules in the same ports are logged and listed normally. Several QSFP-40G-SR-BD units were tried, including a newly purchased one. The Cisco compatibility matrix lists the optic as supported on this switch from NX-OS 7.0(3)I7(1); the poster tested both 7.0(3)I7(1) and 7.0(3)I7(3) without success and attached screenshots of the transceiver and module outputs.

  • Hardware: Cisco Nexus N9K-C93180YC-FX
  • Transceivers: QSFP-40G-SR-BD, QSFP-40GE-LR4
  • Form factor: QSFP+

Symptoms / messages:

QSFP-40G-SR-BD not detected
no syslog message on module insertion
module missing from show interface transceiver
QSFP-40GE-LR4 works in the same ports

Comments 4

A respondent asked for the insertion logs and the port's show output, and another noted that the working QSFP-40GE-LR4 is a single-mode optic while QSFP-40G-SR-BD needs multimode OM3 or better fiber, asking the poster to clarify the cabling.

rx_admin25

A respondent recommended three steps: confirm the QSFP-40G-SR-BD is Cisco-branded, since Cisco does not test or support third-party optics and ruling them out is the first troubleshooting step; upgrade NX-OS to the recommended 9.3(7)/9.3(7a); and upgrade the switch's EPLD/FPGA images to match, because the MI FPGA talks to transceivers over I2C and can cause detection failures or bad SPROM reads.

laser_ops32

Another respondent said that an optic that is detected but does not link should get a hard-coded speed with negotiation disabled, while an optic that is not detected at all is probably third-party; they reported a run of 40G optic and DAC problems with a vendor whose name begins with F and ends in 'ore' (i.e., Fiberstore/FS.com).

coax_eng

A respondent reported that an ACI upgrade broke a batch of brand-new third-party optics on this same switch model and they had to be replaced with Cisco optics; they also endorsed moving to the 9.x long-term release. No resolution was confirmed by the poster.

qsfp_admin
Log in to comment. Log in