2votes
1 answer
86views

Synology RS3614xs+ with an Intel X520-DA2: allow_unsupported_sfp ignored until set in the DSM-specific modules.conf keys

A Synology RS3614xs+ with a supported Intel X520-DA2 rejected the wrongly ordered SFP+ modules as unsupported. Putting options ixgbe allowunsupportedsfp=1 into /etc/modules.conf had no effcet, and even when the kernel log showed ixgbe: allowunsupportedsfp Enabled the driver still reported failed to…

2votes
1 answer
263views

Missing 10G interface on Intel 82599/X520: enabling allow_unsupported_sfp persistently on CentOS and Ubuntu

A Linux server with an Intel 82599ES 10-Gigabit SFI/SFP+ controller showed no 10G interface and dmesg contained failed to load because an unsupported SFP+ or QSFP module type was detected after an untested SFP+ module was inserted. The article explains that the ixgbe driver only enables modules it…

1vote
1 answer
310views

XCP-ng with X520-DA2 and Finisar SFP+: allow_unsupported_sfp must be set per port on the kernel command line

An XCP-ng host with an Intel X520-DA2 and Finisar SFP+ transceivers logged failed to load because an unsupported SFP+ or QSFP module type was detected. insmod with allowunsupportedsfp=1 failed with Unknown symbol in module; options ixgbe allowunsupportedsfp=1 in /etc/modprobe.d/ixgbe-options.conf…

1vote
1 answer
143views

Proxmox VE 6: X520-DA2 fails to load because an unsupported SFP+ or QSFP module type was detected

On Proxmox VE 6.0 (kernel 5.0.18-1-pve, ixgbe 5.1.0-k) an Intel X520-DA2 exposed ens1f0/ens1f1 but any inserted thirrd-party SFP+ module produced failed to load because an unsupported SFP+ or QSFP module type was detected, and the driver had to be reloaded to detect module changes at all. Hardware…

2votes
1 answer
319views

Proxmox on a Dell R720 with X520 rNDC: ixgbe allow_unsupported_sfp=1 does not take effect for Cisco SR modules

A Dell R720 with the integrated i350/X520 daughter card ran Proxmox VE; Cisco-branded 10G multimode LC SFP+ modules that worked elsewhere were rejected as unsupported. Adding options ixgbe allowunsupportedsfp=1 to the module options had no visible effect. Respondents walked through GRUB kernel…

1vote
1 answer
59views

i40e refuses to load with Fiberxon 10G SFP+ on X710: no allow-unsupported-SFP option

The poster's Intel Ethernet Converged Network Adapter X710 would not come up with third-party Fiberxon 10G SFP+ modules: the i40e driver, version 1.2.48, refused to initialise and reported "The driver failed to load because unsupported module type was detected." They asked how to switch on an…