CRS312 to UniFi USW-Pro-48 could only link at 1G after a RouterOS upgrade; the RouterBOARD firmware had not been updated

Asked Active Viewed 143 Original language: English
0

A MikroTik CRS312-4C+8XG (RouterOS 7.13.4) and a Ubiquiti USW-Pro-48 (6.6.61) over 20 m OM3 with SR 850 nm SFP+ optics would only negotiate 1G full duplex; 10G attempts failed with no link and occasional Rx Fault on the UniFi side. Several fibre and transceiver combinations were tested and RouterOS 7.14rc1 did not help.

  • Hardware: MikroTik CRS312-4C+8XG, Ubiquiti USW-Pro-48
  • Transceivers: 10G SFP+ SR 850 nm
  • Form factor: SFP+

Symptoms / messages:

only 1G negotiated
Rx Fault
no link at 10G

Comments 1

Accepted answer

The OS upgrade had ben incomplete: /system routerboard print showed the firmware was not updated although Quick Set claimed success; after properly upgrading both RouterOS and RouterBOARD firmware (second reboot) the link negotiated 10G.

2 South Koreawaverunner63KR Original (English)