2votes
1 answer
263views

Missing 10G interface on Intel 82599/X520: enabling allow_unsupported_sfp persistently on CentOS and Ubuntu

A Linux server with an Intel 82599ES 10-Gigabit SFI/SFP+ controller showed no 10G interface and dmesg contained failed to load because an unsupported SFP+ or QSFP module type was detected after an untested SFP+ module was inserted. The article explains that the ixgbe driver only enables modules it…

6votes
1 answer
218views

Intel X520 in an R630 rejects a 10GBASE-T copper SFP+ with comp_codes_10g=0x00 despite allow_unsupported_sfp=1