CodingBox Q&A Ask question

Top questions

Popular discussions about programming, compatibility and testing of optical transceivers.

354 questions
15 30 50 per page
3votes
3comments
113views

Aruba AP-375 uplink: any way to run a Cisco BiDi SFP, or is the AP locked to approved optics?

We are pushing Wi-Fi into an outbuilding on a campus site. The only fibre going that way is a single strand, so the plan was to hang an AP-375 out there and feed it over a BiDi pair we already had on the shelf. Aruba AP-375, ArubaOS 8 Cisco BiDi SFP in the AP cage, its matching partner wavelength…

6votes
4comments
175views

1G SFP in a Catalyst 3850 uplink module reported unsupported and err-disabled

The poster has a stack of two Cisco Catalyst 3850-48T switches, each fitted with a 2x1G/2x10G fiber uplink network module. Two 10G fiber links already run in slots 2/1/3 and 2/1/4. When a single-mode 1G SFP is inserted into 1G slot 2/1/1, the switch reports the module as unsupported and places the…

4votes
1 answer
102views

CSCwo18785: 'ERROR: The transceiver doesn't support this speed' with a third-party 200G DAC on Nexus 9332D-GX2B

The poster, validating their product against Cisco Nexus 9000 switches (a Nexus C9332D-GX2B chassis), is blocked by bug CSCwo18785: configuring 200G on a QSFP-200G DAC fails with 'ERROR: The transceiver doesn't support this speed'. The cable is a Mellanox MCP1650-H002E26 200GbE DAC; connected…

3votes
2comments
97views

CCR1036-8G-2S+ shows link OK with 1G SFPs but passes no data; the same modules work on a CCR1036-12G-4S

A MikroTik CCR1036-8G-2S+ with S-31DLC20D 1.25G single-mode SFPs reported link OK but no traffic flowed; TX power was blank and RX was -9 dBm. The identical module on the same fibre worked in a CCR1036-12G-4S. Port disable/enable, forcing 1G full duplex on both ends and support tickets did not…

3votes
1 answer
155views

Where to set hw.ix.unsupported_sfp=1 on a Netgate XG-7100 with third-party optics (loader.conf.local vs GUI tunables)

The poster had third-party SFP+ optics for both the on-board Intel X553 ports of a Netgate XG-7100 and an add-in X520-DA2 and had found that hw.ixgbe.unsupportedsfp=1 in /boot/loader.conf enables them. Questions: does it apply to both on-board and PCIe Intel ports, what is the difference between…

2votes
1 answer
54views

pfSense on an 82599 (X520 clone) cannot negotiate 2.5G with an SFP+ RJ45 module to a cable modem

A pfSense router on a Supermicro R210 II with an AOC-STGN-i2S (82599-based X520 clone) was connected throguh an FS.com SFP+-to-RJ45 module to a cable modem with a 2.5 Gbps port. No link negotiation happened; pfSense offered only auto and 10G speeds and never 2.5G. Hardware involved: Supermicro…

4votes
1 answer
112views

Catalyst 3750-X C3KX-NM-10G module reports GLC-SX-MMD as 'Not Present' in some slots

Two Cisco Catalyst 3750-X switches (WS-C3750X-24P-L and WS-C3750X-48P-L) run identical code. A Cisco GLC-SX-MMD is detected normlly in Gi1/1/1 of the first switch, but the second switch reports 'media type is Not Present' with 'link type is force-up' on Gi1/1/1, and 'show idprom interface Gi 1/1/1'…

3votes
2comments
91views

Baudcom GPON ONU SFP stick in a MikroTik hEX S registers on the OLT but the SFP WAN interface cannot route

Replacing the ISP ONU with a Baudcom DB-1234-SFM GPON SFP stick in a hEX S: the stick registered with the OLT and obtained an IP with the spoofed MAC, but with sfp1 as WAN pings returned network unreachable, although the same configuration on ether1 (behind the ISP ONU) worked and Winbox showed no…

0votes
1 answer
21views

Huawei 25GE ports: 10G SFP+ and short copper cables need RS-FEC enabled or the interface stays down

On Huawei switches with 25GE ports the poster asked about using SFP+ transceivers and copper cables; per the troubleshooting docs, when a non-1 m copper cable is connected to a 25GE interface the RS-FEC function must be enabled or the interface goes Down, and mixing different optical modulles at…

3votes
4comments
163views

Speccing 25G and 100G optics for NETGEAR M4500-48XF8C and M4350 when NETGEAR brands none itself

We are building out two racks and the switching is settled: a pair of M4500-48XF8C as the leaves with M4350 underneath. What is not settled is the optics BOM. NETGEAR does not put its own label on 25G or 100G modules, and I would rather not discover after delivery that the SFP28 ports dislike what…

0votes
1 answer
56views

Kernel fixup for Cotsworks SFF modules with invalid EEPROM identity bytes and a bad base checksum

Some Cotsworks SFF fibre modules ship with invalid data in the first EEPROM bytes (physical ID, extended physical ID, connector type) and with checksums programmed before the fields were finalised, so the Linux phy/sfp driveer does not detect them as valid modules. A kernel fixup rewrites the three…

2votes
1 answer
162views

Aruba CX 6200F: no 10G value in the speed command on port 1/1/25 with a Cisco SFP-10G-SR

We are refreshing the core of a small office and put in a pair of Aruba CX 6200F. The link between the two switches is meant to be a 10G trunk on the SFP+ uplinks, and I cannot get either box to admit that 10G exists on that port. 2x Aruba CX 6200F Switch Series, trunk on port 1/1/25 Cisco…

3votes
5comments
143views

Programmer returns WRITE FAIL on an SFP+ that dumps cleanly: dead EEPROM or something blocking writes?

We recode a small batch of modules for customer hosts most months, nothing exotic: read the original page, write the vendor string the host wants, put the module in the switch and move on. One module out of the current batch refuses every write while reading back perfectly, and before I bin it I…

3votes
1 answer
157views

Enabling third-party SFPs on an Aruba 2530-48G-2SFP+: allow-unsupported-transceiver from 16.02.0013

An Aruba/HPE 2530-48G-2SFP+ on firmware 16.01.0012 logged Port contains a transceiver not made by Hewlett Packard Enterprise with the advice to use onlly genuine transceivers, and refused the modules; ironically one of the rejected transceivers was HP-branded. The poster asked whether a command…

2votes
1 answer
109views

MikroTik CSS610 to Cisco Nexus 5596: transceivers detected, no link, four bad fibre patch cords

A MikroTik CSS610-8P-2S+ (SwOS Lite) needed to connect its SFP+ ports to a Cisco Nexus 5596UP. The ports showed the transceivers in the web UI but no link, after trying several fibre cables and transceivers. The switch web UI listed vendor and type for each module, yet the port stayed at no-link…

2votes
1 answer
284views

ethtool -m on Intel X722 fails: Module EEPROM memory read not supported, please update the NVM image

On an Intel S2600WFT board the X722 10GbE SFP+ controller (rev 09, NVM 3.31 0x80000d31 1.1767.0) refused ethtool -m with Cannot get module EEPROM information: Invalid argument, and the kernel logged Module EEPROM memory read not supported. Please update the NVM image. The behaviour was identical…

0votes
1 answer
64views

Kernel SFP quirk for the ODI DFP-34X-2C2 GPON ONU: force 2500BASE-X when the EEPROM does not advertise it

An ODI DFP-34X-2C2 GPON ONU SFP failed to advertise its 2500BASE-X capability because its EEPROM (or virtual EEPROM) did not provide correct speed information to the Linux sfp driver, so the interface did not run at the expected rate. A kernel patch adds a quirk to force the right speed. Hardware…

3votes
4comments
109views

Oracle ZFS Storage ZS3-2: only X2129A and X5562A-Z are listed for the X1109A-Z 10GbE NIC

We took over a pair of ZS3-2 controllers together with the shelves behind them, and I am the one who has to order optics before they go back into service. The controller service manual is very short on this point: it lists the NIC and HBA options, and for the 10GbE SFP+ card it names exactly two…

2votes
3comments
91views

EdgeRouter 4 drops the WAN every 3-60 min with an Alcatel-Lucent GPON SFP: Failed to read SFP EEPROM_1 val -6

After moving a Bell fibre connection from an ER-X to an ER-4 with the ISP's Alcatel-Lucent/Nokia GPON SFP (3FE46541AA / G-010S-P) plugged directly into eth3, the WAN dropped every 3 to 60 minutes; syslog had hundreds of kernel: Failed to read SFP EEPROM1 at byte 0 val -6!! entries and SFP module…

2votes
1 answer
167views

Brocade G610 on FOS 9.x faults compatible 16G SWL optics: Mod_Inv and Speed Mismatch / Incompatible SFP

We are adding capacity to a small FC fabric and bought compatible 16G short-wave SFP+ from an optics supplier instead of paying the switch vendor price. The switch refuses them. Brocade G610, Fabric OS 9.x generic-coded 16G SWL SFP+, correct wavelength and reach according to the label Brocade-coded…

2votes
1comment
51views

TP-Link TL-SM311LM to a SkyLane SFP in a Netgear GS716T: TP-Link side up, Netgear side down, 1 Mbps throughput

A TP-Link T1700G-28TQ (V3, firmware 3.0.0) with a TL-SM311LM module was linked to a Netgear ProSafe GS716T with a SkyLane SFP85P55GE0B989 module. The TP-Link port showed 1000M with a flashing LED while the Netgear port stayed down, and throughput was about 1 Mbps; with a media converter the link…