CodingBox Q&A Ask question

SwOS 2.12 on a CRS305-1G-4S+ breaks SFP-GE-T copper modules that still work on a CRS317

Asked Active Viewed 116 Original language: English
4

After upgrading a CRS305-1G-4S+ to SwOS 2.12, SFP-GE-T 1000BASE-T copper SFPs stopped linking although the switch still identified them in the SFP tab; the same modules kept working on a CRS317-1G-16S+ with the same firmware. Modules inserted before the upgrade continued to work, modules inserted afterwards did not.

  • Hardware: MikroTik CRS305-1G-4S+, MikroTik CRS317-1G-16S+
  • Transceivers: SFP-GE-T 1000BASE-T copper SFP, no-name 1G RJ45 SFP
  • Form factor: SFP

Symptoms / messages:

module identified but no link after firmware upgrade

Comments 3

Disable flow control (SwOS 2.12 had a pause-frame bug that left links stuck).

4 United Statesphotonrunner70US Original (English)

Disable auto-negotiation and set speed manually; copper modules then linked, but failed again once auto-negotiation was re-enabled (fibre modules unaffected).

4 Argentinaportbear20AR Original (English)

Force 1G, reboot SwOS, then re-enable auto-negotiation; rported to make no-name RJ45 SFPs work.

4 United Statesphotonrunner70US Original (English)
Log in to comment. Log in