Top questions
Popular discussions about programming, compatibility and testing of optical transceivers.
On a Mellanox SN2410 (MLNX-OS 3.6.4112) a 100G port connected to a Chelsio adapter through a 2 m unequalised QSFP copper cable would not link when FEC was disabled; no HSS lane signal was detected on the adapter side. The poster required FEC-off operaation and asked whether the switch supports it…
The two SFP ports (F1/F2) of a Brocade ICX6450-C12-PD, licnesed for 10G, would not come up with either a Brocade 1000BASE-LR SFP (33211-100) or 10GBASE-SR moduls over a 5 m single-mode patch to an ICX6450-24P. show media saw the transceivers but the interface reported GigabitEthernet1/3/1 is down…
A first-time SFP+ deployment between a UniFi 16XG switch and a Tehuti Networks TN9310 SFP+ adapter, with transceivers the reseller called compatible, produced an Rx fault indication in the UniFi controller. Swapping the fibre ends (polarity) did not help. Hardware involved: Ubiquiti US-16-XG…
The poster configured new HP 2530-48G switches (J9281B) with J9775A SFP+ direct-attach cables bought as accessories. The ports stayed down and the log said FFI: port 49 Transceiver type not supported in this port; show tech transceivers first showed nothing and, afer upgrading from YA.15.12.0007 to…
A Mellanox ConnectX-3 40GbE NIC connected with Mellanox QSFP passive copper cables (MC2210126-005) to a Dell PowerConnect 8164 (firmware 5.1.4.5) produced a link-up event for a few seconds followed by a permanent link-down. The same cables worked NIC-to-NIC, and Dell refused support because the…
With two dual-port Mellanox ConnectX-4 cards, a MikroTik SFP+ switch, 1 m OM4 patches and mixed 10G/25G transceivers from several vendors, one NIC port showed link UP but got no DHCP and could not route, 25G transceivers negotiated only 1G, and previously stable 10G links dropped intermittently…
2votes
2comments
171views
The poster uses Ubiquiti (UBNT) SFP and SFP+ modules, both multimode and single-mode, in Cisco switches. They work perfectly in Catalyst 9300 and 3650 switches with current IOS, but in a Catalyst C1000 and a Catalyst 2960 the modules are detected on insertion yet reported as 'unknown' in 'show…
On an HP 5120-EI the poster inserted an Allied Telesis AT-SPEX 1310 nm SFP and got a PHONY ENTITY trap plus OPTMOD/4/FIBERSFPMODULENOWINVALID: This is not a supported transceiver for this platform; the port never came up. The poster looked for a command to disable enforcement of SFP coding. Later…
2votes
2comments
274views
The poster, a new owner of a Cisco Nexus 93180YC-EX running NX-OS 7.0(3)I4(7), cannot bring up any 25G link. ipolex SFP28 DAC cables are recognized ('type is SFP-H25GB-CU1M', 'name is OEM', 'part number is SFP-H25G-CU1M', 'nominal bitrate is 25500 MBit/sec', 'DOM is not supported') but the port…
The poster asked whether third-party optics can be used in an HPE FlexFabric 5700 40XG 2QSFP+ (JG896A) and whether the ProVision command allow-unsupported-transceiver exists on it. The answer clarified how Comware differs from ProVision: there is no allow-list of supported transceivers, so unlisted…
The poster wanted to dump the EEPROM of a QSFP+ transceiver plugged into an Intel XL710-QDA1 and ideally read live DDM values such as received optical power, as they were used to doing with SFP modules on other adatpers. With i40e 2.0.23 and firmware 5.05 0x800028a2 1.1568.0, ethtool -m eth0…
A FlexFabric 5900AF running Comware 7.1.035 R2208P01 reported a third-party transceiver as not supported when inserted, while the same class of modules worked in a FlexFabric 7904 on 7.1.045. The poster asked whether support could be enabled by command and whether the Comware versin mattered…
Two Cisco Nexus 93108TC-FX3P switches on NX-OS 9.3(11) are connected with genuine QSFP-100G-CU1M DACs but the link never comes up. The compatibility matrix says the cable is supported from NX-OS 9.3.5. The port config is a plain 'switchport mode trunk' / 'no shutdown', and 'show interface eth1/54…
2votes
2comments
182views
The poster (in a machine-translated post from the Spanish-language community) tried to connect two Cisco Business CBS350-24T-4X switches through their SFP+ ports using MikroTik XS+2733LC15D modules. No connectivity is established and the ports end up blocked by the switch's Link Flap Prevention…
While building a trunk between a Cisco Catalyst 3650-48PS and a Catalyst 3560CX-12PC using Cisco GLC-T copper SFPs at both ends, the 3560CX logged '%PHY-4-SFPNOTSUPPORTED: The SFP in Gi0/11 is not supported' and the link would not come up. The poster had already tried 'no errdisable detect cause…
Intel X710/XL710 adapters refuse third-party optics at the firmwre level with the message Rx/Tx is disabled on this device because an unsupported SFP module type was detected, and the i40e driver offers no override. The repository documents a procedure to remove the check: update to a known…
The poster is searching for GPON or XGS-PON SFP ONT sticks with a built-in MAC that work in Cisco routers, since Cisco does not sell such modules. Previous attempts with third-party ONT sticks were largely unsuccessful even after enabling 'service unsupported-transceiver'. In a follow-up the poster…
Two service providers shared a fibre with CWDM multiplexers. The existing 1310 nm channel worked, but after adding a 1471 nm channel the transmitting side saw frames leave (confirmed with packet captures) while the far end received nothing, even though light levels looked normal. The provider had…
On a Lanner NCA-1510 the four Intel X553 ports (ix0-ix3) worked, but two Intel I210 Gigabit Fiber Network Connection interfaces (device 0x15368086) with SFP cages were absent in OPNsense even after loading ifigb via tunables; pfSense detected them by default. Another user had the same with a…
Before replacing an old switch with a Cisco Catalyst 9300-M, the poster wanted to know whetther the existing SFP could be reused and posted the 'show idprom interface gigabitEthernet 1/1/1' output: Vendor Name CISCO-FINISAR, Vendor Part Number FTLF1318P2BCL-C3, serial FNS15510U5B, 1310 nm, single…
On Debian 8.11 (kernel 3.16) the poster ran ethtool -m on a Mellanox MT26448 adapter to read optical diagnostics (TX/RX power, temperature, voltage, thresholds) and got Cannot get module EEPROM information: Input/output error. Hardware involved: Mellanox MT26448 ConnectX-2, SFP+ optic with DDM…
The poster runs temporary event networks and has twice hit heavy frame errors on 10G links between MikroTik and Cisco switches. About a year earlier a Cisco Catalyst 2960-S with 10G uplinks connected to a MikroTik CRS317-1G-16S+ showed CRC errors on the Cisco side and swapping cables did not help…
On an HP 5820-24XG-SFP+ (JC102A) the ports cabled with genuine HP X240 10G SFP+ 3 m DACs (JD097C) came up but logged OPTMOD/4/FIBERSFPMODULENOWINVALID: This is not a supported transceiver for this platform, and broadcast/multicast counters on those ports grew faster than normal. The cable is lisetd…
An out-of-the-box ES-48-Lite (1.9.3) was connected to an EdgeRouter Infinity ER-8-XG (2.0.9-hotfix.2) with a UF-RJ45-10G module on each side and a Cat6 cable. A laptop on the switch obtained a DHCP lease from the router only after about a minute and then could not reach the router or the internet…
0votes
2comments
150views
Speccing the uplinks for an M4300-96X before the order goes in, and the 40G side has turned into a dead end that I would like to sanity check with people who have actually built one. NETGEAR M4300-96X chassis APM402XL port card for the 40G QSFP+ ports planned: two 40GBASE-X runs to the neighbouring…
On an Aruba 1930 (JL685A, software 2.6.0) two D-NET DN-SFP-LX modules in SFP+ ports 49 and 50 actually carried traffic, yet the web dashboard showed both ports as DOWN and, without a CLI, the poster could not check whether the modules were identified. The question was whether this was a bug, an…
The poster operated old HP/H3C A5800 switches (JC100A, JC103A) with many SFP modules of mixed coding. Modules with H3C in A0h bytes 60h-62h worked but logged This is not a supported transceiver for this platform, and DDM plus serial/date information were unavailable. Copying the full data from a…
The poster tried to link an HPE FlexFabric 5900AF and a Dell S5212F-ON at 10 Gbps with DAC cables that had been custom-made with an HPE-coded end and a Dell-coded end. Both ports were forced to 10G full duplex, but no link came up. On the HPE side the interface reported Media type is stack wire…
Mellanox ConnectX-3 MCX314A-BCBT and MCX354A-FCB cards (firmware 2.42.5000, driver 5.50.14740.1) were detected in Windows 11 and Ubuntu 22.10 but no optical transceiver ever emitted light: Cisco QSFP-40G-SR-BD, Cisco SFP-10G-SR and Mellanox MFM1T02A-SR were tried on LC-LC OM3, aross three…
A proposed ixgbe patch would have let X550EM NICs recognise otherwise-unsupported 1G copper SFPs by treating them as 1G SX through a new module parameter, mirroring the existing unsupported-SFP handling. Without the change these NICs simply refuse the copper module, so operators wanting cheap 1G…