On a Juniper EX4600 running Junos 14.1X53-D27.3 the poster inserted a non-certifiied 1G single-mode WDM (BiDi) SFP, 20 km, TX 1550 / RX 1310 nm with DDM, into ge-0/0/1. The interface never appeared: show interfaces returned error: device ge-0/0/1 not found, and the log recorded XCVR: Unit 1, Fibre…
5votes
4comments
276views
A network operator received QFX3500 switches that would not bring up thhird-party SFP+ transceivers even though a Juniper sales engineer had said they would work. JTAC stated that non-Juniper SFP+ optics would never be supported on the platform. The switch detected the presence of the module but…
While staging an EX2300-48P and an EX2300-24P (both Junos 18.2R3-S5.3) with non-Juniper SFP+/SFP moules, the 48-port switch recognised the transceivers and created interfaces, but the 24-port switch showed nothing in any of its four uplink ports; show chassis hardware listed PIC 1 as 4x10G SFP/SFP+…
Juniper-branded SFP modules were intermittently reported as unsupported or not supported in the chassis hardware output right after an EX or MX device booted. Rebooting the device or reseating the SFP made the module recognised again, which was frustrating in production. The poster wanted to know…
The poster needed to connect a MikroTik CRS328-4C-20S-4S+RM to an HP 1820-24G-PoE+ over 200-500 m of outdoor aerial fibre and asked which SFP modules to buy and how to verify compatibility before purchase. The HP compatibility table listed only J4859C as a single-mode SFP, while MikroTik offered…
The poster wanted to run 100 Mbps fibre SFP modules in a D-Link DES-3200-28F but the vendor compatibility list only named older switches (DES-1228, DES-1252, DGS-3612G). The question was whether the list was simply stale or whether the modules would be rejected by the newer switch. A related…
The poster owned a MikroTik RB962UiGS-5HacT2HnT (hAP ac) with a single SFP cage and had two spare 850 nm modules on hand: a Cisco-branded AFBR-57F5PZ-CS1 and an Intel-branded FTLX8571D3BCVIT1. The ISP delivered the service over a single fibre strand rather than a duplex pair, and the posster wanted…
The thread starter had a set of Cisco EEPROM images (SX, LH, ZX types) but no CWDM images and wanted CWDM SFP modules to show up on Cisco switches as CWDM/WDM optics rather than being misidentified as SX or LX. Without a correct image the switch either reported the module as unsupported or forced…
3votes
2comments
269views
The poster planned a server with an Intel X710-DA2 dual-port SFP+ NIC connected to two Ubiquiti EdgeSwitch 48 Lite units, with LACP between the switches. Six 10G SFP+ modules were needed (two for the server side, four for the switches) and the question was which modules would be recognised by both…
For a deployment on Dell PowerEdge R630 and C4140 servers the poster had Intel X520-SR2 adapters (E10G42BFSR) fitted with the bundled Intel FTLX8571D3BCV-I3 10GBASE-SR SFP+ modules (850 nm, 300 m multimode). The uplink switch is a Huawei Quidway 9300 whose SFP+ ports carry 10GBASE-LR (1310 nm)…
The poster spent a day and a half chasing an Intel 82599EB-based 10G SFP+ NIC that VMware ESXi 6 reported as down although the link LEDs were green on both ends of the fibre and the Cisco 8500 switch showed the port up/up. The cause turned out to be the Cisco SFP-10G-LRM module used throuhout their…
The poster's Cisco Catalyst C9500-48Y4C switches (IOS XE 16.12.04 after an upgrade) refuse to work with a batch of genuine Cisco SFP-10G-SR modules (VID V03, serials AVD2231D3TE and AVD2231D3RW): 'show inventory' lists them as 'GE ZX' instead of 'SFP+ 10GBASE-SR' and the ports stay non-functional…
The poster, validating their product against Cisco Nexus 9000 switches (a Nexus C9332D-GX2B chassis), is blocked by bug CSCwo18785: configuring 200G on a QSFP-200G DAC fails with 'ERROR: The transceiver doesn't support this speed'. The cable is a Mellanox MCP1650-H002E26 200GbE DAC; connected…
While rolling out single-mode fiber between Cisco CBS350-8MGP-2X switches (firmware 3.4.0.17) with SFP-10G-LR modules, the poster hit strange behaviour: the link only comes up if the duplex LC connector is split and the TX fiber is inserted first, then the RX fiber. Inserting the joined LC…
4votes
2comments
314views
The poster connects a Cisco Catalyst C9300X-24Y to a FortiGate firewall with a 25G SFP-H25G-CU2M DAC. Whenever the DAC is inserted the switch logs '%PLATFORMPM-6-MODULEINSERTED: SFP module inserted with interface name Twe1/0/23' followed by '%PLATFORMPM-6-DIFFERENTMODULEINSERTED: Warning: SFP…
A Cisco Nexus 5672UP fitted with a 10GBASE-SR SFP+ could not connect to another switch that uses a 1000BASE-SX (1 Gbps) transceiver; both ends are multimode optics. When the poster changed the port speed, 'show interface brief' displayed an 'SFP checksum error', and swapping the Nexus optic for a 1…
The poster is searching for GPON or XGS-PON SFP ONT sticks with a built-in MAC that work in Cisco routers, since Cisco does not sell such modules. Previous attempts with third-party ONT sticks were largely unsuccessful even after enabling 'service unsupported-transceiver'. In a follow-up the poster…
Before replacing an old switch with a Cisco Catalyst 9300-M, the poster wanted to know whetther the existing SFP could be reused and posted the 'show idprom interface gigabitEthernet 1/1/1' output: Vendor Name CISCO-FINISAR, Vendor Part Number FTLF1318P2BCL-C3, serial FNS15510U5B, 1310 nm, single…
On an IOS XR router (RSP-based ASR 9000 class, observed on IOS XR 4.x and 5.x), the poster configured a tunable DWDM XFP with 'controller dwdm 0/1/0/0', 'admin-state maintenance', 'wavelength 55', 'admin-state in-service' and then brought the TenGigE interface up. The running configuration shows…
The poster's newly acquired Cisco Catalyst 9300 (with an 8-port 10G SFP+ network module) would not link to a Cisco Catalyst 4503-E tat only has 1G SFP ports. Suspecting a 10G-versus-1G speed mismatch, the poster tried to force the 9300's 10G SFP to operate at 1G with the 'speed' command, but the…
Two Cisco Nexus 93108TC-FX3P switches on NX-OS 9.3(11) are connected with genuine QSFP-100G-CU1M DACs but the link never comes up. The compatibility matrix says the cable is supported from NX-OS 9.3.5. The port config is a plain 'switchport mode trunk' / 'no shutdown', and 'show interface eth1/54…
2votes
2comments
171views
The poster uses Ubiquiti (UBNT) SFP and SFP+ modules, both multimode and single-mode, in Cisco switches. They work perfectly in Catalyst 9300 and 3650 switches with current IOS, but in a Catalyst C1000 and a Catalyst 2960 the modules are detected on insertion yet reported as 'unknown' in 'show…
The poster asked whether anyone had used third-party optcis in a Cisco Catalyst 9300 series switch running IOS XE Everest (16.x), and specifically whether the hidden global command 'service unsupported-transceiver', long used on older Catalyst platforms to accept non-Cisco SFPs, still functions on…
3votes
2comments
143views
The poster needs a 100GE link between a Cisco NCS55A2-MOD (NC55-MPA-4H-S MPA) and a Cisco Catalyst C9500-48Y4C using a QSFP-100G-CU1M DAC. Both platforms list the cable as supported, yet the link never comes up at the physical level. Because the Catalyst 9500 lacks 100G auto-negotiation (bug…
The poster was connecting a Cisco Nexus 93180YC-FX to an Arista 7050SX3 with a 25G AOC sold as Cisco/Arista compatible. The Nexus detects the transceiver, but 'show interface status' reports the port as not connected. A 10G AOC from the same vendor works fine between the two switches, and the same…
3votes
3comments
205views
The poster wanted to run a link bidirectionally over one strand of single-mode fiber on a Cisco Small Business 300 series switch. Cisco's SMB catalogue lists the MFEBX1 100 Mb BiDi SFP (transmitting at 1310 nm and receiving at 1550 nm), but the poster could not find a Cisco part number for the…
The poster spent two days trying to bring up a single-mode fiber link between an older Arista switch and a Cisco Catalyst 3650 (IOS-XE 3.7.5) with Cisco GLC-LH-SMD (SFP-LH-SMD) optics; the path runs through five patch cords in the same building and had been tested by the cabling contractor. At…
2votes
2comments
274views
The poster, a new owner of a Cisco Nexus 93180YC-EX running NX-OS 7.0(3)I4(7), cannot bring up any 25G link. ipolex SFP28 DAC cables are recognized ('type is SFP-H25GB-CU1M', 'name is OEM', 'part number is SFP-H25G-CU1M', 'nominal bitrate is 25500 MBit/sec', 'DOM is not supported') but the port…
The poster runs temporary event networks and has twice hit heavy frame errors on 10G links between MikroTik and Cisco switches. About a year earlier a Cisco Catalyst 2960-S with 10G uplinks connected to a MikroTik CRS317-1G-16S+ showed CRC errors on the Cisco side and swapping cables did not help…
On a Cisco Nexus N9K-C93180YC-FX, QSFP-40G-SR-BD BiDi modules are not detected at all: nothing appears in the logs when they are inserted and they are absent from 'show interface transceiver', whereas QSFP-40GE-LR4 modules in the same ports are logged and listed normally. Several QSFP-40G-SR-BD…