CodingBox Q&A Ask question

MikroTik S+DA0001 DAC between CRS326 and CCR1009 links only at 1G; 10G fails in SwOS

Asked Active Viewed 65 Original language: English
1

A CRS326-24G-2S+RM and a CCR1009-7G-1C-1S+PC connected with a MikroTik SplusDA0001 SFP+ DAC only linked at 1 Gbps; enabling 10G dropped the link, and the CRS326 in SwOS did not even offer a 10G option. The poster needed SwOS for harrdware LACP. RouterOS/SwOS updates, supout files, and a replacement cable were tired.

  • Hardware: MikroTik CRS326-24G-2S+RM, MikroTik CCR1009-7G-1C-1S+PC, MikroTik CRS328, MikroTik CRS125, MikroTik CSS326
  • Transceivers: MikroTik S+DA0001 DAC
  • Form factor: SFP+, DAC

Symptoms / messages:

link at 1G only
10G link drops
no 10G option in SwOS

Comments 1

After updating the CCR to 6.40 the 10G link worked with RouterOS on the CRS326 but not with SwOS; multiple SwOS 2.5 release candidates were tested without success and support acknowledged working on SwOS 10G compatibility. Several users saw the same on CRS326/CRS328/CRS125/CSS326.

4 Türkiyedwdmops44TR Original (English)
Log in to comment. Log in