0votes
0comments
109views

Dell S5212F-ON to Cisco C9500-48Y4C: dual-coded FS SFP28 DACs stay protocol down while 2 m Cisco/Cisco cables link

Between VxRail Dell S5212F-ON TOR switches and Cisco C9500-48Y4C switches, FS.com SFP28 DACs behaved inconsistently: a 5 m cable custom-coded Cisco on one end and Dell on the other came Line Up, Protocol down; a 2 m Cisco/Cisco-coded cable linked; a 3 m cable would not link even with the 2 m…

2votes
1 answer
99views

Connecting a UDM SE 10G SFP+ port to an Enterprise XG 24 SFP28 port: which DAC, and the mixed-speed limitation

The poster wanted to connect a UDM SE (10G SFP+) to an Enterprise XG 24 switch (25G SFP28) and asked whether an SFP+ DAC would work with the SFP28 port falling back to 10G, or whether an SFP28 DAC was preferable. The concern was whether the SFP28 cage would fall back to 10G with an ordinary SFP+…

1vote
2comments
107views

Diagnosing a ConnectX-4 port with link but no traffic and 25G optics negotiating only 1G on a MikroTik switch

With two dual-port Mellanox ConnectX-4 cards, a MikroTik SFP+ switch, 1 m OM4 patches and mixed 10G/25G transceivers from several vendors, one NIC port showed link UP but got no DHCP and could not route, 25G transceivers negotiated only 1G, and previously stable 10G links dropped intermittently…

0votes
1comment
237views

ConnectX-4 Lx reports Cable is unplugged with FS.com SFP28-25GLR-31 modules over 40 m OS2

A Mellanox ConnectX-4 Lx (MCX4121A-ACAAx, firmware 14.32.1900) in a Ryzen desktop (Fedora 41 and Windows 10) detected the interface but reported Cable is unplugged with two FS.com SFP28-25GLR-31 modules and a 40 m single-mode LC duplex patch; a MikroTik router recognised the same optics. The poster…

3votes
4comments
163views

Speccing 25G and 100G optics for NETGEAR M4500-48XF8C and M4350 when NETGEAR brands none itself

We are building out two racks and the switching is settled: a pair of M4500-48XF8C as the leaves with M4350 underneath. What is not settled is the optics BOM. NETGEAR does not put its own label on 25G or 100G modules, and I would rather not discover after delivery that the SFP28 ports dislike what…

4votes
2comments
314views

Catalyst C9300X-24Y resets FEC to auto when an SFP-H25G-CU2M DAC is inserted, breaking the link to a FortiGate

The poster connects a Cisco Catalyst C9300X-24Y to a FortiGate firewall with a 25G SFP-H25G-CU2M DAC. Whenever the DAC is inserted the switch logs '%PLATFORMPM-6-MODULEINSERTED: SFP module inserted with interface name Twe1/0/23' followed by '%PLATFORMPM-6-DIFFERENTMODULEINSERTED: Warning: SFP…