ConnectX-4 Lx MCX4121A-ACAT advertises only 10000baseKR: link to a 10GBASE-R device passes no traffic until firmware 14.30.1004
A ConnectX-4 Lx EN MCX4121A-ACAT (25GbE dual SFP28, firmware 14.27.1016) on Linux Mint 19.3 / kernel 5.4 is connected to equipment that only speaks 10GBASE-R variants (SR/CR, no KR). A link comes up but no data is transmitted or received. ethtool lists 10000baseKR/Full as the only 10G mode next to 25G CR/KR/SR. Does this card realy support only 10GBASE-KR at 10G, and would a Mellanox-validated module change anything?
Comments 2
The 10000baseKR label in mlx5 ethtool output does not mean the cage is limited to a backplanne-only 10G connection. The reported MCX4121A-ACAT case began passing traffic after firmware 14.30.1004 was installed.
Check the qualified module list and the firmware fix history. An unchanged displayed mode name after the successful update shows why the label alone is insufficient evidence of an optical-mode incompatibility.