4votes
1 answer
162views

Solarflare SFN7122F under TrueNAS: card is detected, but working multimode SFP+ modules stay dark

Building a storage box at home and picked up a dual 10GbE Solarflare SFN7122F (SFC9120) because it was cheap. The card itself looks healthy, the system sees it and both ports enumerate, but not one of my existing multimode SFP+ modules will bring up a link in it. Solarflare SFN7122F, dual port…

3votes
5comments
143views

Programmer returns WRITE FAIL on an SFP+ that dumps cleanly: dead EEPROM or something blocking writes?

We recode a small batch of modules for customer hosts most months, nothing exotic: read the original page, write the vendor string the host wants, put the module in the switch and move on. One module out of the current batch refuses every write while reading back perfectly, and before I bin it I…

4votes
3comments
124views

Napatech capture SmartNICs: what actually happens with an SFP+ that is not in the qualified list

We run packet capture on a handful of Napatech cards and I am putting together the optics order for the next rack. Before spending anything I want to understand what the qualified module list actually means in practice, because the wording leaves room for interpretation. Napatech NT40E3 and NT20E3…

3votes
4comments
109views

Oracle ZFS Storage ZS3-2: only X2129A and X5562A-Z are listed for the X1109A-Z 10GbE NIC

We took over a pair of ZS3-2 controllers together with the shelves behind them, and I am the one who has to order optics before they go back into service. The controller service manual is very short on this point: it lists the NIC and HBA options, and for the 10GbE SFP+ card it names exactly two…

4votes
1 answer
181views

EX4200 reports the SFP+ EEPROM as mis-programmed after a Junos upgrade while an MX960 still shows DOM

We run a handful of 80 km DWDM spans off EX4200s with third-party optics on both ends, because the vendor-branded DWDM parts were never going to fit the budget. That was fine for years. After the EX boxes were moved to Junos 12.3 the optics still sit in the same ports and the spans still exist, but…

6votes
6comments
209views

Third-party DWDM SFP+ stays down on an Arista 7050T with EOS 4.10.6 - anything short of patching the image?

We run a small regional network and pulled a spare 7050T out of stock to use as a DWDM aggregation box. Arista-coded DWDM optics for it quote close to the price of the switch, so we bought third-party DWDM SFP+ instead, and now the switch will not talk to them. Arista 7050T, EOS 4.10.6 generic…

5votes
6comments
78views

Third-party SFP+ optics stay down on a second-hand DCS-7150S-24: is the enable3px flash file still an option?

I picked up a couple of second-hand Arista switches for the lab and ran straight into the optics gate. Arista-coded modules link up, passive DAC cables link up, and anything third-party leaves the port down. The lab side: DCS-7150S-24, bought used, no support contract and no account team behind me…

8votes
1 answer
163views

About 15% packet loss through an S+RJ10 copper SFP+ on a CRS518-16XS-2XQ while the direct 100G path is clean

We push traffic from a lab server into a CRS518-16XS-2XQ over a 100G QSFP28 uplink, and it leaves the switch through a MikroTik S+RJ10 copper SFP+ into a plain 1G RJ45 host. The receiving side is missing a large share of the packets and I cannot pin it on anything obvious. Setup: MikroTik…

7votes
5comments
304views

Lenovo RackSwitch G8124E refuses a generic 10G SR SFP+ with UNAPPROVED - SR SFP+ is DISABLED

We pulled a pair of G8124E out of a decommissioned rack and I am rebuilding them as the aggregation layer for an internal test environment. Budget for branded optics is zero, so everything goes in with generic 10G SR modules of the type we already run elsewhere. Lenovo RackSwitch G8124E, ex-IBM…

5votes
1 answer
134views

Supermicro E300-9A on pfSense Plus 22.05: ix2 and ix3 stay at no carrier with a DAC that links fine on a USW-Aggregation

My firewall is a Supermicro E300-9A running pfSense Plus 22.05, and both 10G SFP+ ports refuse to come up. Neither ix2 nor ix3 ever shows carrier, whatever I put in the cage. Hardware: Supermicro E300-9A, pfSense Plus 22.05 Ubiquiti DAC-SFP10-0.5M and a 10Gtek passive twinax cable Supermicro…

Indonesia sfpeng49 ID asked
5votes
1 answer
120views

Sun Network 10GbE Switch 72p: x2129a 1G module in an SFP+ port stays down while 10G neighbours are fine

I inherited a Sun Network 10GbE Switch 72p with a couple of legacy boxes hanging off it that will never do more than a gigabit. The plan was to drop a 1G capable module into one of the SFP+ cages and be done with it. Sun Network 10GbE Switch 72p, SEFOS CLI over the serial console x2129a dual-rate…

6votes
1 answer
218views

Intel X520 in an R630 rejects a 10GBASE-T copper SFP+ with comp_codes_10g=0x00 despite allow_unsupported_sfp=1

We are consolidating a pair of R630s onto 10G and the cabling to the top of the rack is copper, so instead of pulling fibre I put 10GBASE-T SFP+ modules into the X520 cards. The switch end takes them without a word. The servers refuse to. Dell PowerEdge R630, Intel X520 (82599), dual port FS…