CodingBox Q&A Ask question

Questions tagged “Ubiquiti”

19 questions
15 30 50 per page
0votes
1 answer
192views

UCG-Fiber with a UACC-CM-RJ45-MG never recovers the link after the far-end Zyxel XS1930 reboots; DAC fixed it

A UCG-Fiber used a UACC-CM-RJ45-MG 10GBASE-T module (port 6, later port 7) to reach a Zyxel XS1930. Whenever the copper cable was disconnected for more than about 40 s or the Zyxel rebooted, the link never came back until the module was pulled for a minute or the gateway rebooted; forcing 10G or 1G…

0votes
1comment
91views

ES-48-Lite to ER-8-XG over two UF-RJ45-10G modules and Cat6: DHCP takes a minute and traffic will not pass

An out-of-the-box ES-48-Lite (1.9.3) was connected to an EdgeRouter Infinity ER-8-XG (2.0.9-hotfix.2) with a UF-RJ45-10G module on each side and a Cat6 cable. A laptop on the switch obtained a DHCP lease from the router only after about a minute and then could not reach the router or the internet…

3votes
2comments
138views

UDM SE recognises a 30 m UACC-AOC-SFP10 but logs an SFP EEPROM error and the Minisforum MS-01 X710 never lights the port

A short no-name DAC between a UDM SE and a Minisforum MS-01 had worked for months; a new 30 m Ubiquiti UACC-AOC-SFP10-30M active optical cable was recognised by the UDM SE (vendor, part, serial, temperrature, power visible) but no link came up and the SFP port log showed an SFP EEPROM error; on…

2votes
1 answer
99views

Connecting a UDM SE 10G SFP+ port to an Enterprise XG 24 SFP28 port: which DAC, and the mixed-speed limitation

The poster wanted to connect a UDM SE (10G SFP+) to an Enterprise XG 24 switch (25G SFP28) and asked whether an SFP+ DAC would work with the SFP28 port falling back to 10G, or whether an SFP28 DAC was preferable. The concern was whether the SFP28 cage would fall back to 10G with an ordinary SFP+…

2votes
2comments
111views

UDM Pro to US-16-150W over a 1 m Ubiquiti DAC: link light on the switch only, even with both ports forced to 1G

A UDM Pro (port 11 set to 1G) and a US-16-150W (port 17) connected by a 1 m Ubiquiti DAC (UDC-1) did not talk: the switch showed a link light, the UDM Pro showed nothing. Setting both sides to 1G and rebooting both devices did not help; reversing the cable and removing the parallel copper uplink…

3votes
2comments
107views

ADDON JD097C-AO DAC links two US-48-500W switches but not the US-16-XG, which still reads the cable EEPROM

An ADDON JD097C-AO SFP+ DAC worked between two US-48-500W (firmware 3.3.11.3850) but not from a US-48-500W to a US-16-XG (3.7.39.6089): no link lights on either side and forcing 10G made no difference, although mca-dump on the XG showed the module fully parsed (sfpfound true, vendor ADDON, part…

1vote
1comment
102views

EdgeRouter 4 logs Failed to read SFP EEPROM_1 at byte 0 val -11 with a Bell Huawei MA5671A GPON stick

An EdgeRouter 4 (EdgeOS 1.10.0) with the GPON SFP taken from a Bell Home Hub 3000 (Huawei MA5671A, SC connector, DDM readable: 50.9 C, 3.25 V, 8.87 mA, TX 1.36 mW, RX 0.02 mW) logged kernel: Failed to read SFP EEPROM1 at byte 0 val -11!! twelve times a minute although the internet worked. Removing…

1vote
2comments
55views

UniFi UNAS Pro and UNVR 10G SFP+ ports drop to 1G after firmware updates or power cycles until the module is reseated

On two sites a UNAS Pro (UniFi RJ45 SFP+ module) and a UNVR (UniFi fibre SFP+ module) dropped to 1G after every firmware update or power cycle; rebooting the device, the port or the switch did not help, only physically pulling and reinserting the module (or reseating the fibre) restored an…

2votes
3comments
91views

EdgeRouter 4 drops the WAN every 3-60 min with an Alcatel-Lucent GPON SFP: Failed to read SFP EEPROM_1 val -6

After moving a Bell fibre connection from an ER-X to an ER-4 with the ISP's Alcatel-Lucent/Nokia GPON SFP (3FE46541AA / G-010S-P) plugged directly into eth3, the WAN dropped every 3 to 60 minutes; syslog had hundreds of kernel: Failed to read SFP EEPROM1 at byte 0 val -6!! entries and SFP module…

2votes
2comments
144views

UniFi switches on firmware 7.2.123: SFP+ optics and DACs flap, STP flapping alerts, ports need reboot or forced 1G

After UniFi Network 10.0.140 / switch firmware 7.2.123 several operators saw SFP+ ports (UI optics, UACC-OM-MM-10G-D, MikroTik XS+DA0001 DACs, UACC-CM-RJ45-MG copper modules) flapping on US-XG-16, USW Pro Max, UDM Pro and USW-24-Pro units, with STP State Flapping alerts, ports blocked, and switches…

0votes
1 answer
187views

EdgeSwitch ES-24 will not link to HP/Netgear/Juniper/Cisco over 1G SX SFPs until the peer disables auto-negotiation

Newly delivered EdgeSwitch ES-24 units linked to each other over gigabit SX SFPs, but the same modules (HP J4858B, J4858A, Avago AFBR-57M5APZ, Avaya AFBR5715PZ, Cisco) would not link ES-24 to HP ProCurve (four models) or Netgear (two models): the ES-24 showed a link light, the other side did not…

0votes
1 answer
142views

CRS312 to UniFi USW-Pro-48 could only link at 1G after a RouterOS upgrade; the RouterBOARD firmware had not been updated

A MikroTik CRS312-4C+8XG (RouterOS 7.13.4) and a Ubiquiti USW-Pro-48 (6.6.61) over 20 m OM3 with SR 850 nm SFP+ optics would only negotiate 1G full duplex; 10G attempts failed with no link and occasional Rx Fault on the UniFi side. Several fibre and transceiver combinations were tested and RouterOS…

3votes
2comments
269views

Which SFP+ modules to buy for EdgeSwitch 48 Lite uplinks and an Intel X710-DA2 server NIC

The poster planned a server with an Intel X710-DA2 dual-port SFP+ NIC connected to two Ubiquiti EdgeSwitch 48 Lite units, with LACP between the switches. Six 10G SFP+ modules were needed (two for the server side, four for the switches) and the question was which modules would be recognised by both…