CodingBox Q&A Ask question

Questions tagged “SFP+”

75 questions
15 30 50 per page
2votes
2comments
120views

Do DrayTek Vigor2962 and VigorSwitch G2540x take third-party SFP+ optics, or only DrayTek modules?

We are moving the office uplinks from copper to fibre and the quote that came back has DrayTek-branded optics in every line. Before I start arguing about the difference against ordinary 10G modules I would like to know whether the hardware actually cares what sits in the cage, because the…

2votes
1 answer
162views

Aruba CX 6200F: no 10G value in the speed command on port 1/1/25 with a Cisco SFP-10G-SR

We are refreshing the core of a small office and put in a pair of Aruba CX 6200F. The link between the two switches is meant to be a 10G trunk on the SFP+ uplinks, and I cannot get either box to admit that 10G exists on that port. 2x Aruba CX 6200F Switch Series, trunk on port 1/1/25 Cisco…

3votes
1 answer
72views

Aruba 2540 uplink ports 51-52 stay Down on an inter-building run while a 2530 links the same modules

I look after a two-building site and the access switches were replaced with Aruba 2540s a while back. The fibre between the buildings has not been touched, but since the swap the uplink refuses to come up. Aruba 2540 on our side, ports 51 and 52 used for the uplinks Aruba J4858D 1000SX in the 2540…

3votes
1 answer
78views

1G SFP stays dark in a DrayTek VigorSwitch FX2120 SFP+ cage while the same module links elsewhere

I look after a small office network and put in a DrayTek VigorSwitch FX2120 to get a 10G core. Both 10G links, to the router and to the NAS, came up on their own within seconds. What I cannot do is get a single 1G device onto the switch through the SFP+ cages. Switch: DrayTek VigorSwitch FX2120…

5votes
1 answer
165views

Dell DD9900 in an HA pair doesn't see the SFP on ethMa: State UP, link status NO, Cannot get module EEPROM information

I run a backup storage system in a data center. A pair of DD9900 in HA, network ports on the NDC QLogic. After a reboot or reseating the module, port ethMa stops seeing the transceiver, and it's not a one-off - it's a stable, repeating pattern. Dell DD9900, DD OS 7.2.0.95, HA configuration NDC…

Russia portrunner91 RU asked
2votes
1 answer
167views

Brocade G610 on FOS 9.x faults compatible 16G SWL optics: Mod_Inv and Speed Mismatch / Incompatible SFP

We are adding capacity to a small FC fabric and bought compatible 16G short-wave SFP+ from an optics supplier instead of paying the switch vendor price. The switch refuses them. Brocade G610, Fabric OS 9.x generic-coded 16G SWL SFP+, correct wavelength and reach according to the label Brocade-coded…