CodingBox Q&A Ask question

All questions

Latest questions from the community.

355 questions
15 30 50 per page
6votes
1 answer
97views

IC-prog dumps 256 bytes off an SFP, but the second half is a copy of the first, page A2 doesn't read (HP 2530-24G)

I run a small ISP's network and regularly reflash cheap modules for HP. Usual task: flash the vendor module's image into cheap Chinese 1.25G WDM modules so the switch accepts them without complaint. Donor is a J4859C, target hardware is an HP 2530-24G J9776A. What's on the bench: HP 2530-24G J9776A…

Russia wavetech RU asked
1vote
3comments
138views

Enabling a third-party transceiver on HPE FlexFabric 5900AF: no CLI switch, ask the supplier to code it for HP 5900

A FlexFabric 5900AF running Comware 7.1.035 R2208P01 reported a third-party transceiver as not supported when inserted, while the same class of modules worked in a FlexFabric 7904 on 7.1.045. The poster asked whether support could be enabled by command and whether the Comware versin mattered…

7votes
5comments
304views

Lenovo RackSwitch G8124E refuses a generic 10G SR SFP+ with UNAPPROVED - SR SFP+ is DISABLED

We pulled a pair of G8124E out of a decommissioned rack and I am rebuilding them as the aggregation layer for an internal test environment. Budget for branded optics is zero, so everything goes in with generic 10G SR modules of the type we already run elsewhere. Lenovo RackSwitch G8124E, ex-IBM…

5votes
1 answer
134views

Supermicro E300-9A on pfSense Plus 22.05: ix2 and ix3 stay at no carrier with a DAC that links fine on a USW-Aggregation

My firewall is a Supermicro E300-9A running pfSense Plus 22.05, and both 10G SFP+ ports refuse to come up. Neither ix2 nor ix3 ever shows carrier, whatever I put in the cage. Hardware: Supermicro E300-9A, pfSense Plus 22.05 Ubiquiti DAC-SFP10-0.5M and a 10Gtek passive twinax cable Supermicro…

Indonesia sfpeng49 ID asked
3votes
1 answer
157views

Enabling third-party SFPs on an Aruba 2530-48G-2SFP+: allow-unsupported-transceiver from 16.02.0013

An Aruba/HPE 2530-48G-2SFP+ on firmware 16.01.0012 logged Port contains a transceiver not made by Hewlett Packard Enterprise with the advice to use onlly genuine transceivers, and refused the modules; ironically one of the rejected transceivers was HP-branded. The poster asked whether a command…

5votes
1 answer
120views

Sun Network 10GbE Switch 72p: x2129a 1G module in an SFP+ port stays down while 10G neighbours are fine

I inherited a Sun Network 10GbE Switch 72p with a couple of legacy boxes hanging off it that will never do more than a gigabit. The plan was to drop a 1G capable module into one of the SFP+ cages and be done with it. Sun Network 10GbE Switch 72p, SEFOS CLI over the serial console x2129a dual-rate…

1vote
1 answer
226views

Why third-party SFP+ still fail on Aruba 3810M/2930M with allow-unsupported-transceiver: the HPIDv2 flag at byte 0x7B

Even with allow-unsupportted-transceiver enabled, HPE Aruba 3810M and 2930M switches showed an amber fault for generic SFP+ modules, including ones recoded to masquerade as a J9151A. The author traced the behaviour to HPE's HPIDv2 challenge-response authentication: the module EEPROM carries a flag…

United States netwizard14 US asked