6votes
1 answer
218views

Intel X520 in an R630 rejects a 10GBASE-T copper SFP+ with comp_codes_10g=0x00 despite allow_unsupported_sfp=1

We are consolidating a pair of R630s onto 10G and the cabling to the top of the rack is copper, so instead of pulling fibre I put 10GBASE-T SFP+ modules into the X520 cards. The switch end takes them without a word. The servers refuse to. Dell PowerEdge R630, Intel X520 (82599), dual port FS…

0votes
1 answer
132views

CWDM link: 1310 nm channel works, new 1471 nm channel carries no traffic despite good light levels

Two service providers shared a fibre with CWDM multiplexers. The existing 1310 nm channel worked, but after adding a 1471 nm channel the transmitting side saw frames leave (confirmed with packet captures) while the far end received nothing, even though light levels looked normal. The provider had…

3votes
2comments
269views

Which SFP+ modules to buy for EdgeSwitch 48 Lite uplinks and an Intel X710-DA2 server NIC

The poster planned a server with an Intel X710-DA2 dual-port SFP+ NIC connected to two Ubiquiti EdgeSwitch 48 Lite units, with LACP between the switches. Six 10G SFP+ modules were needed (two for the server side, four for the switches) and the question was which modules would be recognised by both…

1vote
1 answer
59views

i40e refuses to load with Fiberxon 10G SFP+ on X710: no allow-unsupported-SFP option

The poster's Intel Ethernet Converged Network Adapter X710 would not come up with third-party Fiberxon 10G SFP+ modules: the i40e driver, version 1.2.48, refused to initialise and reported "The driver failed to load because unsupported module type was detected." They asked how to switch on an…

4votes
1 answer
102views

CSCwo18785: 'ERROR: The transceiver doesn't support this speed' with a third-party 200G DAC on Nexus 9332D-GX2B

The poster, validating their product against Cisco Nexus 9000 switches (a Nexus C9332D-GX2B chassis), is blocked by bug CSCwo18785: configuring 200G on a QSFP-200G DAC fails with 'ERROR: The transceiver doesn't support this speed'. The cable is a Mellanox MCP1650-H002E26 200GbE DAC; connected…

5votes
1 answer
274views

XL710-QDA2 disables Rx/Tx with non-Intel QSFP+ cables: "unsupported SFP+ module type" in i40e

The poster compiled and loaded i40e 3.4.2 on Ubuntu 16.04 for an Intel XL710-QDA2 dual-port 40GbE adapter. The driver loaded fine, but as soon as non-Intel QSFP+ cables were attached dmesg reported "Rx/Tx is disabled on this device because an unsupported SFP+ module type was detected." and no link…

2votes
1 answer
225views

CBS350 SFP-10G-LR link only comes up when the TX fiber is inserted before RX; faulty transceiver pair

While rolling out single-mode fiber between Cisco CBS350-8MGP-2X switches (firmware 3.4.0.17) with SFP-10G-LR modules, the poster hit strange behaviour: the link only comes up if the duplex LC connector is split and the TX fiber is inserted first, then the RX fiber. Inserting the joined LC…

4votes
2comments
314views

Catalyst C9300X-24Y resets FEC to auto when an SFP-H25G-CU2M DAC is inserted, breaking the link to a FortiGate

The poster connects a Cisco Catalyst C9300X-24Y to a FortiGate firewall with a 25G SFP-H25G-CU2M DAC. Whenever the DAC is inserted the switch logs '%PLATFORMPM-6-MODULEINSERTED: SFP module inserted with interface name Twe1/0/23' followed by '%PLATFORMPM-6-DIFFERENTMODULEINSERTED: Warning: SFP…

0votes
1 answer
115views

Nexus 93108TC-FX3P: QSFP-100G-CU1M link only comes up when speed is set before inserting the cable

Two Cisco Nexus 93108TC-FX3P switches on NX-OS 9.3(11) are connected with genuine QSFP-100G-CU1M DACs but the link never comes up. The compatibility matrix says the cable is supported from NX-OS 9.3.5. The port config is a plain 'switchport mode trunk' / 'no shutdown', and 'show interface eth1/54…