An open-source hardware and software project to read and modify SFP/SFP+ EEPROM, aimed at changing the OUI and other identity fields so a module works with third-party transceivers where the vendor has not fully disabled write access. It uses a Cypress CY8CKIT-059 board as the USB interface. As of…
On two sites a UNAS Pro (UniFi RJ45 SFP+ module) and a UNVR (UniFi fibre SFP+ module) dropped to 1G after every firmware update or power cycle; rebooting the device, the port or the switch did not help, only physically pulling and reinserting the module (or reseating the fibre) restored an…
After a power outage an Aruba Instant On 1930 (24 ports plus 4 SFP) still recognised inserted SFP modules but every SFP port stayed down; inserting a new transceiver made the port LED blink once and then nothing. The poster asked for diagnostics or replacement options. Hardware involved: Aruba…
The poster could read and write OEM SFP variants with a REVELPROG and SFP adapter but not three Finisar references, suspecting manufacturer password protection. Finisar only documents the MSA user-EEPROM password in datasheets, not the proprietary manufacturer password, and the same happened with…
All 10G ports on a Netgear M5300-28G3 were used, so the poster asked whether a Cisco 3 m SFP+ DAC (H10GB-CU3M) or Finisar FTLX8571D3BCL 10G SR modules could be used in the switch's 1G SFP ports to add another 10G-capable device at reduced speed. Hardware involved: Netgear M5300-28G3, Cisco…
The two SFP ports (F1/F2) of a Brocade ICX6450-C12-PD, licnesed for 10G, would not come up with either a Brocade 1000BASE-LR SFP (33211-100) or 10GBASE-SR moduls over a 5 m single-mode patch to an ICX6450-24P. show media saw the transceivers but the interface reported GigabitEthernet1/3/1 is down…
While building a trunk between a Cisco Catalyst 3650-48PS and a Catalyst 3560CX-12PC using Cisco GLC-T copper SFPs at both ends, the 3560CX logged '%PHY-4-SFPNOTSUPPORTED: The SFP in Gi0/11 is not supported' and the link would not come up. The poster had already tried 'no errdisable detect cause…
A MikroTik CRS312-4C+8XG (RouterOS 7.13.4) and a Ubiquiti USW-Pro-48 (6.6.61) over 20 m OM3 with SR 850 nm SFP+ optics would only negotiate 1G full duplex; 10G attempts failed with no link and occasional Rx Fault on the UniFi side. Several fibre and transceiver combinations were tested and RouterOS…
On an HP 5120-EI the poster inserted an Allied Telesis AT-SPEX 1310 nm SFP and got a PHONY ENTITY trap plus OPTMOD/4/FIBERSFPMODULENOWINVALID: This is not a supported transceiver for this platform; the port never came up. The poster looked for a command to disable enforcement of SFP coding. Later…
The poster asked whether third-party optics can be used in an HPE FlexFabric 5700 40XG 2QSFP+ (JG896A) and whether the ProVision command allow-unsupported-transceiver exists on it. The answer clarified how Comware differs from ProVision: there is no allow-list of supported transceivers, so unlisted…
A FLYPRO SFP-1G-CS-100M 1000BASE-T module in a MikroTik CRS112-8P-4S (RouterOS 6.47.10) was detected but reported no-link with sfp-rx-loss: yes, whatever the far end (MikroTik LHG/RB750Gr3, Ubiquiti, Cisco). Fixed 1G speeds, other module units and rebootts were tried; only a Ubiquiti switch linked…
The poster is searching for GPON or XGS-PON SFP ONT sticks with a built-in MAC that work in Cisco routers, since Cisco does not sell such modules. Previous attempts with third-party ONT sticks were largely unsuccessful even after enabling 'service unsupported-transceiver'. In a follow-up the poster…
A FlexFabric 5900AF running Comware 7.1.035 R2208P01 reported a third-party transceiver as not supported when inserted, while the same class of modules worked in a FlexFabric 7904 on 7.1.045. The poster asked whether support could be enabled by command and whether the Comware versin mattered…
In a home lab with an Aruba S2500 PoE switch and an Intel X520-DA2, three of thirteen cheaply bought Intel AFBR-703SDZ-IN2 SFP+ modules (around 15 USD each) failed within three months: links dropped with dark activity LEDs, two on the switch side and one on the NIC side. Warm and cold reboots…
A first-time SFP+ deployment between a UniFi 16XG switch and a Tehuti Networks TN9310 SFP+ adapter, with transceivers the reseller called compatible, produced an Rx fault indication in the UniFi controller. Swapping the fibre ends (polarity) did not help. Hardware involved: Ubiquiti US-16-XG…