CodingBox Q&A Ask question

Top questions

Popular discussions about programming, compatibility and testing of optical transceivers.

468 questions
15 30 50 per page
1vote
2comments
108views

Diagnosing a ConnectX-4 port with link but no traffic and 25G optics negotiating only 1G on a MikroTik switch

With two dual-port Mellanox ConnectX-4 cards, a MikroTik SFP+ switch, 1 m OM4 patches and mixed 10G/25G transceivers from several vendors, one NIC port showed link UP but got no DHCP and could not route, 25G transceivers negotiated only 1G, and previously stable 10G links dropped intermittently…

0votes
1 answer
133views

CWDM link: 1310 nm channel works, new 1471 nm channel carries no traffic despite good light levels

Two service providers shared a fibre with CWDM multiplexers. The existing 1310 nm channel worked, but after adding a 1471 nm channel the transmitting side saw frames leave (confirmed with packet captures) while the far end received nothing, even though light levels looked normal. The provider had…

0votes
1 answer
118views

Eight new J9150D transceivers fail with Unsupported Transceiver (SelftTest Err#098000) on a 5406R zl2: all counterfeit

The poster bought eight J9150D 10G SR SFP+ transceivers for an Aruba 5406R zl2 chassis with a J9993A module. Every module lit the orange LED and logged Unsupported Transceiver. (SelftTest Err#098000), even though the compatibility documents list this combination and the chassis had already been…

1vote
1comment
103views

EdgeRouter 4 logs Failed to read SFP EEPROM_1 at byte 0 val -11 with a Bell Huawei MA5671A GPON stick

An EdgeRouter 4 (EdgeOS 1.10.0) with the GPON SFP taken from a Bell Home Hub 3000 (Huawei MA5671A, SC connector, DDM readable: 50.9 C, 3.25 V, 8.87 mA, TX 1.36 mW, RX 0.02 mW) logged kernel: Failed to read SFP EEPROM1 at byte 0 val -11!! twelve times a minute although the internet worked. Removing…

0votes
1 answer
116views

Nexus 93108TC-FX3P: QSFP-100G-CU1M link only comes up when speed is set before inserting the cable

Two Cisco Nexus 93108TC-FX3P switches on NX-OS 9.3(11) are connected with genuine QSFP-100G-CU1M DACs but the link never comes up. The compatibility matrix says the cable is supported from NX-OS 9.3.5. The port config is a plain 'switchport mode trunk' / 'no shutdown', and 'show interface eth1/54…

1vote
1comment
129views

ethtool -m on a Mellanox MT26448 (ConnectX-2) returns Input/output error: DOM readout not supported on EOL adapters

On Debian 8.11 (kernel 3.16) the poster ran ethtool -m on a Mellanox MT26448 adapter to read optical diagnostics (TX/RX power, temperature, voltage, thresholds) and got Cannot get module EEPROM information: Input/output error. Hardware involved: Mellanox MT26448 ConnectX-2, SFP+ optic with DDM…

1vote
1comment
127views

ConnectX-3 40GbE with Mellanox QSFP DACs to a Dell PowerConnect 8164: link comes up briefly then stays down

A Mellanox ConnectX-3 40GbE NIC connected with Mellanox QSFP passive copper cables (MC2210126-005) to a Dell PowerConnect 8164 (firmware 5.1.4.5) produced a link-up event for a few seconds followed by a permanent link-down. The same cables worked NIC-to-NIC, and Dell refused support because the…

United States txnode67 US asked