CodingBox Q&A Ask question

Top questions

Popular discussions about programming, compatibility and testing of optical transceivers.

468 questions
15 30 50 per page
1vote
2comments
127views

Checking from 'show idprom' whether an old CISCO-FINISAR 1000BASE-LX SFP can be reused in a Catalyst 9300-M

Before replacing an old switch with a Cisco Catalyst 9300-M, the poster wanted to know whetther the existing SFP could be reused and posted the 'show idprom interface gigabitEthernet 1/1/1' output: Vendor Name CISCO-FINISAR, Vendor Part Number FTLF1318P2BCL-C3, serial FNS15510U5B, 1310 nm, single…

1vote
1comment
171views

Aruba Instant On 1930 shows SFP+ ports DOWN in the dashboard with third-party D-NET LX modules that pass traffic

On an Aruba 1930 (JL685A, software 2.6.0) two D-NET DN-SFP-LX modules in SFP+ ports 49 and 50 actually carried traffic, yet the web dashboard showed both ports as DOWN and, without a CLI, the poster could not check whether the modules were identified. The question was whether this was a bug, an…

0votes
2comments
151views

NETGEAR M4300-96X with APM402XL: no NETGEAR QSFP+ optics exist, so what goes in the 40G ports

Speccing the uplinks for an M4300-96X before the order goes in, and the 40G side has turned into a dead end that I would like to sanity check with people who have actually built one. NETGEAR M4300-96X chassis APM402XL port card for the 40G QSFP+ ports planned: two 40GBASE-X runs to the neighbouring…

0votes
1comment
69views

ONLP onlp_sfp_eeprom_read shifts QSFP EEPROM data on an Accton Wedge100BF (every other byte dropped)

On an Accton Wedge100BF-32x the ONLP call onlpsfpeepromread returned QSFP EEPROM data with alternating bytes skipped, so vendor strings appeared with every other symbol missing; the same transceiver read correctly on an Accton AS7312-54x. The vendor name FINISAR CORP appeared at the wrong offset…

0votes
1comment
125views

OPNsense on a Lanner NCA-1510 does not detect the two Intel I210 fibre SFP interfaces that pfSense sees

On a Lanner NCA-1510 the four Intel X553 ports (ix0-ix3) worked, but two Intel I210 Gigabit Fiber Network Connection interfaces (device 0x15368086) with SFP cages were absent in OPNsense even after loading ifigb via tunables; pfSense detected them by default. Another user had the same with a…

0votes
1comment
85views

SFP Access Port: RP2040-based open hardware to read and write SFP/SFP+ embedded EEPROM over USB

An open hardware/firmware project to read and write the EEPROM inside SFP and SFP+ modules so their capailities and vendor origin can be inspected and modified. It uses an RP2040 microcontroller and exposes a USB Mass Storage interface. The project is a work in progress and does not yet document…

0votes
1comment
92views

ES-48-Lite to ER-8-XG over two UF-RJ45-10G modules and Cat6: DHCP takes a minute and traffic will not pass

An out-of-the-box ES-48-Lite (1.9.3) was connected to an EdgeRouter Infinity ER-8-XG (2.0.9-hotfix.2) with a UF-RJ45-10G module on each side and a Cat6 cable. A laptop on the switch obtained a DHCP lease from the router only after about a minute and then could not reach the router or the internet…

0votes
1comment
64views

Genuine versus third-party SFP/SFP+ on Extreme switches: DDMI not readable on an X620, no vendor support

The poster had free thrid-party SFP/SFP+ samples that worked on Extreme switches and asked whether to buy genuine or third-party modules. A respondent reported that on a new X620 a third-party SFP+ linked but its DDMI data could not be read, and that Extreme provides no help for problems involving…

0votes
1comment
31views

1G optics in MikroTik SFP+ ports: forced 1G fails to an RBFTC11 while auto-negotiation causes FCS errors to a CRS328

Contradicting MikroTik's documented advice to force 1G full duplex when using 1G optics in SFP+ ports, a Netpower Lite 7R linked to an RBFTC11 only with auto-negotiation (forced 1G gave link up but zero received packets), while the same Netpower to a CRS328-4C-20S-4S+ had heavy packet loss and FCS…