Dell Force10 S4810 warns Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M on a third-party DAC

Monitoring reported packet loss toward an ESXi iSCSI host; on the Dell S4810 (FTOS 9.11(2.6)) the interface TenGigabitEthernet 0/37 showed the warning Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M because a non-Dell DAC was used. The link was up with normal traffic (about 16…

0votes
0comments
151views

Intel X710 in a Dell R740xd links with 2013 Cisco DACs (VID V02) but not 2019 ones (V03) of the same part number

Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the…

0votes
0comments
54views

Cisco-compatible CWDM SFPs that worked in PowerConnect 6024/6224 report transmit failure in an 8024F

Cisco-compatible CWDM SFP modules that had worked in Dell PowerConnect 6024 and 6224 switches produced a transmit failure error in a PowerConnect 8024F, presumably because the 8024F ports are SFP+. The poster considered Finisar FWLF1524P2Vxx modules but wanted confirmation from someone with a…

0votes
0comments
109views

Dell S5212F-ON to Cisco C9500-48Y4C: dual-coded FS SFP28 DACs stay protocol down while 2 m Cisco/Cisco cables link

Between VxRail Dell S5212F-ON TOR switches and Cisco C9500-48Y4C switches, FS.com SFP28 DACs behaved inconsistently: a 5 m cable custom-coded Cisco on one end and Dell on the other came Line Up, Protocol down; a 2 m Cisco/Cisco-coded cable linked; a 3 m cable would not link even with the 2 m…

1vote
1comment
126views

ConnectX-3 40GbE with Mellanox QSFP DACs to a Dell PowerConnect 8164: link comes up briefly then stays down

A Mellanox ConnectX-3 40GbE NIC connected with Mellanox QSFP passive copper cables (MC2210126-005) to a Dell PowerConnect 8164 (firmware 5.1.4.5) produced a link-up event for a few seconds followed by a permanent link-down. The same cables worked NIC-to-NIC, and Dell refused support because the…

United States txnode67 US asked
3votes
1 answer
228views

Fixing no carrier with Flypro 10GBASE-T SFP+ on a Dell-branded X520-DA2 under Debian and FreeBSD/OPNsense

A Dell-branded Intel X520-DA2 with Flypro 10GBASE-T SFP+ modules showed no carrier (or no interface at all) on Debian and on FreeBSD-based OPNsense because the card rejects unapproved modules. The post collects the per-OS fixes and the permanent EEPROM approach. Hardware involved: Dell-branded…

5votes
1 answer
165views

Dell DD9900 in an HA pair doesn't see the SFP on ethMa: State UP, link status NO, Cannot get module EEPROM information

I run a backup storage system in a data center. A pair of DD9900 in HA, network ports on the NDC QLogic. After a reboot or reseating the module, port ethMa stops seeing the transceiver, and it's not a one-off - it's a stable, repeating pattern. Dell DD9900, DD OS 7.2.0.95, HA configuration NDC…