Device support
Programmers, coding boards, switches, NICs and other hardware
Small home rack, one server and one switch. I replaced an XGS1250-12 with an XS1930-10 and the only thing that did not survive the swap is the server uplink. Zyxel XS1930-10, SFP+ port with media type set to DAC10G Asus XG-C100F in the server 10Gtek CAB-10GSFP-P5M, 5 m passive twinax, AWG26 a…
We are bringing up a pair of AS9716-32D as a 400G spine in the lab, on a community SONiC image with the PDDF platform layer. The optics are not the problem, the peer links fine, but everything the switch says about them is wrong. Edgecore AS9716-32D (x8664-acctonas971632d-r0) community SONiC build…
Setting up 10G between a server and a TP-Link switch, nothing exotic. The card shows up in the system, driver loads normally, but there's no link on the port at all - no errors, no negotiation attempts. server: Intel X710, four 10GbE SFP+ ports, firmware 9.140.76856 TP-Link switch, SFP+ port cable…
7votes
5comments
304views
We pulled a pair of G8124E out of a decommissioned rack and I am rebuilding them as the aggregation layer for an internal test environment. Budget for branded optics is zero, so everything goes in with generic 10G SR modules of the type we already run elsewhere. Lenovo RackSwitch G8124E, ex-IBM…
My firewall is a Supermicro E300-9A running pfSense Plus 22.05, and both 10G SFP+ ports refuse to come up. Neither ix2 nor ix3 ever shows carrier, whatever I put in the cage. Hardware: Supermicro E300-9A, pfSense Plus 22.05 Ubiquiti DAC-SFP10-0.5M and a 10Gtek passive twinax cable Supermicro…
Trying to replace the ISP terminal in my home rack with a GPON stick straight in the router, so the fibre lands in one box instead of two. The stick is recognised, and that is where the good news ends. Turris Omnia on Turris OS 5.0.3, stock kernel Huawei MA5671A GPON stick with unlocked firmware…
5votes
5comments
121views
We have a dark fibre span of roughly 80 km where the owner will lease us exactly one strand - a second core is either not there or priced like a small building. Both ends terminate on chassis with XFP cages, and the service on top of it has to be 10 GbE. So what I need is a single-fibre BiDi XFP…
4votes
4comments
150views
I keep a shelf of pulled SFPs at home and I would like to be able to read their EEPROM, repair a module whose checksum got mangled, and occasionally recode one for a switch that is picky about vendor strings. Buying a commercial programmer for a handful of modules a year makes no sense here, so I…
5votes
4comments
276views
We are refreshing a pair of aggregation closets and the optics line is the part management keeps poking at. The switches are EXOS boxes and the plan was to fill the 40G uplinks with generic QSFP+ DACs, the same way we already do on the access ports. Then someone on the team dug up a note about a…
I finally moved my VDSL2 line off the ISP box and terminated it on the Turris Omnia itself, mostly so that PPPoE runs on the router instead of on a second device in bridge mode. The setup part was pleasant: seat the stick in the cage and the WAN interface simply moves onto the module, leaving the…
3votes
2comments
193views
The poster wanted to connetc Aruba 2540 switches (JL357A, firmware YC.16.09.0001) to Cisco Catalyst 9300 switches using Cisco SFP-H10GB-CU3M DACs. After enabling allow-unsupported-transceiver the cables were still not recognised: show tech transceivers listed the port as unsupported, the LED…
I inherited a Sun Network 10GbE Switch 72p with a couple of legacy boxes hanging off it that will never do more than a gigabit. The plan was to drop a 1G capable module into one of the SFP+ cages and be done with it. Sun Network 10GbE Switch 72p, SEFOS CLI over the serial console x2129a dual-rate…
We are standing up four DGX Spark nodes for disttributed training and hung them off a MikroTik CRS812-8DS-2DQ-2DDQ. The plan was one 400G QSFP-DD port on the switch feeding two nodes at 200G each, so a couple of breakout cables cover the whole cluster. MikroTik CRS812-8DS-2DQ-2DDQ, QSFP-DD ports…
Two Flex System enclosures, each with an EN4093R 10Gb Scalable Switch (option 49Y4270) as the network module. Ports come back error-disabled after a chassis power event, and less often drop into the same state while everything is running. It is not always the same ports, which is what makes this so…
Rebuilding aggregation at one of our sites: a CRS326-24S+2Q+RM takes the custmer SFP+ ports and uplinks over 40G into a Huawei S6720. Short run inside the same rack, so a passive DAC rather than optics. MikroTik CRS326-24S+2Q+RM, QSFP+ port qsfpplus1-1 Huawei S6720-54C-EI-48S-AC, plain 40GE port…