Device support
Programmers, coding boards, switches, NICs and other hardware
8votes
7comments
176views
We are bringing up a leaf on an Accton AS9716-32D running SONiC master (build master.207726). Four of the 400G-capable ports have to run at 100G towards a firewall pair, and not one of them will link. Accton AS9716-32D, SONiC master.207726 INNOLIGHT TR-FC13R-N00 QSFP28 LR4 in the switch cage…
The poster had an Integra Optics tunable DWDM SFP+ (1528.77-1566.72 nm, 96 channels, 80 km, 10G, sold as Calix/Arista compatible) in an Arista switch. Changing the frequency and configuring the ITU channel through the Arista CLI had no effect: the module kept reporting the same wavelength. The…
Two service providers shared a fibre with CWDM multiplexers. The existing 1310 nm channel worked, but after adding a 1471 nm channel the transmitting side saw frames leave (confirmed with packet captures) while the far end received nothing, even though light levels looked normal. The provider had…
With an Aruba 2930F connected to a server through a Stornet-branded J9283D-SN passive 3 m SFP+ DAC, port 50 dropped the link immediately after it came up and port 52 flapped with the log message FFI : Port: 52 Excessive link state transitions. The same cable worked on ports 49 and 51, and fibre…
On a Juniper EX4600 running Junos 14.1X53-D27.3 the poster inserted a non-certifiied 1G single-mode WDM (BiDi) SFP, 20 km, TX 1550 / RX 1310 nm with DDM, into ge-0/0/1. The interface never appeared: show interfaces returned error: device ge-0/0/1 not found, and the log recorded XCVR: Unit 1, Fibre…
5votes
4comments
276views
A network operator received QFX3500 switches that would not bring up thhird-party SFP+ transceivers even though a Juniper sales engineer had said they would work. JTAC stated that non-Juniper SFP+ optics would never be supported on the platform. The switch detected the presence of the module but…
The poster needed to connect a MikroTik CRS328-4C-20S-4S+RM to an HP 1820-24G-PoE+ over 200-500 m of outdoor aerial fibre and asked which SFP modules to buy and how to verify compatibility before purchase. The HP compatibility table listed only J4859C as a single-mode SFP, while MikroTik offered…
The poster wanted to verify whether an HPE StorageWorks 81B 8 Gb Fibre Channel HBA (AP769-60001) fitted with an AJ716B SFP could be used in an HPE ProLiant DL380 Gen10 server (P02464-B21) and asked for a tool where part numbers can be entered to get a compatibility verdict. No error had occurred…
The poster wanted a cheap 10G link between servers with Intel X520-DA2 NICs and an HP switch and worried that a direct-attach cable is coded either for Intel or for HP but not both. A respondent shared that two X520-DA2 cards would not link directly over a DAC in their case, but a Dell DAC…
The poster wanted to run 100 Mbps fibre SFP modules in a D-Link DES-3200-28F but the vendor compatibility list only named older switches (DES-1228, DES-1252, DGS-3612G). The question was whether the list was simply stale or whether the modules would be rejected by the newer switch. A related…
The poster owned a MikroTik RB962UiGS-5HacT2HnT (hAP ac) with a single SFP cage and had two spare 850 nm modules on hand: a Cisco-branded AFBR-57F5PZ-CS1 and an Intel-branded FTLX8571D3BCVIT1. The ISP delivered the service over a single fibre strand rather than a duplex pair, and the posster wanted…
The thread starter had a set of Cisco EEPROM images (SX, LH, ZX types) but no CWDM images and wanted CWDM SFP modules to show up on Cisco switches as CWDM/WDM optics rather than being misidentified as SX or LX. Without a correct image the switch either reported the module as unsupported or forced…
The thread starter wanted to reprogram GBIC and SFP module EEPROMs but found that guides were disappearing from forums. Questions covered which programmer to use, where to attach the I2C lines on the module, whether the module needs 5 V (GBIC) or 3.3 V (SFP), and how to treat the memory as a…
3votes
2comments
269views
The poster planned a server with an Intel X710-DA2 dual-port SFP+ NIC connected to two Ubiquiti EdgeSwitch 48 Lite units, with LACP between the switches. Six 10G SFP+ modules were needed (two for the server side, four for the switches) and the question was which modules would be recognised by both…
A brand-new retail Intel E810-XXVDA2 on Windows Server 2022 (Intel driver 1.12.164.0 from release package 28) was connected to an SFP28 port of a Ubiquiti USW-Pro-Aggregation switch. With an SFP28 DAC the link came up at 25G immediately, but with SFP28 optical transceivers (Ubiquiti…