Top questions
Popular discussions about programming, compatibility and testing of optical transceivers.
On an Accton Wedge100BF-32x the ONLP call onlpsfpeepromread returned QSFP EEPROM data with alternating bytes skipped, so vendor strings appeared with every other symbol missing; the same transceiver read correctly on an Accton AS7312-54x. The vendor name FINISAR CORP appeared at the wrong offset…
Contradicting MikroTik's documented advice to force 1G full duplex when using 1G optics in SFP+ ports, a Netpower Lite 7R linked to an RBFTC11 only with auto-negotiation (forced 1G gave link up but zero received packets), while the same Netpower to a CRS328-4C-20S-4S+ had heavy packet loss and FCS…
An open hardware/firmware project to read and write the EEPROM inside SFP and SFP+ modules so their capailities and vendor origin can be inspected and modified. It uses an RP2040 microcontroller and exposes a USB Mass Storage interface. The project is a work in progress and does not yet document…
0votes
0comments
118views
Monitoring reported packet loss toward an ESXi iSCSI host; on the Dell S4810 (FTOS 9.11(2.6)) the interface TenGigabitEthernet 0/37 showed the warning Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M because a non-Dell DAC was used. The link was up with normal traffic (about 16…
The poster tried a Mellanox MFA2P10-Axxx 25G SFP28 AOC between a MikroTik switch and a Supermicro server with an Intel X722 (ixl driver) under pfSense. The cable linked fine switch-to-switch but on the X722 ifconfig -vvvm showed the module recognised (10GBase-SFI, 1000Base-KX listed) yet no carrier…
The poster had free thrid-party SFP/SFP+ samples that worked on Extreme switches and asked whether to buy genuine or third-party modules. A respondent reported that on a new X620 a third-party SFP+ linked but its DDMI data could not be read, and that Extreme provides no help for problems involving…
With auto-negotiation on, CRS317 and CRS326 SFP+ interfaces ran at 10G; with auto-negotiation=no, speed=10Gbps and full-duplex=yes the log still reported link up (speed 1G, full duplex) regardless of the advertise settings. On a CCR1009 the same configuration produced no-link instead, showing that…
A Mellanox ConnectX-4 Lx (MCX4121A-ACAAx, firmware 14.32.1900) in a Ryzen desktop (Fedora 41 and Windows 10) detected the interface but reported Cable is unplugged with two FS.com SFP28-25GLR-31 modules and a 40 m single-mode LC duplex patch; a MikroTik router recognised the same optics. The poster…
With an Aruba 2930F connected to a server through a Stornet-branded J9283D-SN passive 3 m SFP+ DAC, port 50 dropped the link immediately after it came up and port 52 flapped with the log message FFI : Port: 52 Excessive link state transitions. The same cable worked on ports 49 and 51, and fibre…
0votes
0comments
151views
Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the…
Cisco-compatible CWDM SFP modules that had worked in Dell PowerConnect 6024 and 6224 switches produced a transmit failure error in a PowerConnect 8024F, presumably because the 8024F ports are SFP+. The poster considered Finisar FWLF1524P2Vxx modules but wanted confirmation from someone with a…
After a complete power loss a Dell R740 with a four-port Broadcom NDC (2x SFP+, 2x 1GbE) booted normally but the fibre SFP+ modules stayed unpowered and disconnected; a reboot did not help and only physically removing and reinserting the modules restored them. Dell support pointed at drivers and…
0votes
0comments
109views
Between VxRail Dell S5212F-ON TOR switches and Cisco C9500-48Y4C switches, FS.com SFP28 DACs behaved inconsistently: a 5 m cable custom-coded Cisco on one end and Dell on the other came Line Up, Protocol down; a 2 m Cisco/Cisco-coded cable linked; a 3 m cable would not link even with the 2 m…
A QSFP28 100 Gb DAC supplied by Supermicro linked two Dell S5248F-ON (OS10 10.4.3.6) switches fine, but between the Dell and a Supermicro XEM-100 the port showed up, line protocol is down. Multiple FEC and negotiation combinations were tried. The thread received no answers. Hardware involved: Dell…
0votes
0comments
172views
With a CSS326-24G-2S+ (SwOS 2.6) and a server with an Intel 82599 card, two different S+DA0001 DACs and two Intel cards never linked; two CSS326 switches connected by DAC only achieved 1 Gbps. A later reader on SwOS 2.12 with an 82599 reported the same. No solution was posted. Hardware involved…