CodingBox Q&A Ask question

All questions

Latest questions from the community.

354 questions
15 30 50 per page
1vote
1comment
72views

SFP Doctor: open hardware/software to read and rewrite SFP OUI and identity when write access is not locked

An open-source hardware and software project to read and modify SFP/SFP+ EEPROM, aimed at changing the OUI and other identity fields so a module works with third-party transceivers where the vendor has not fully disabled write access. It uses a Cypress CY8CKIT-059 board as the USB interface. As of…

2votes
1 answer
100views

Cisco module signature: bytes 96-127 must match the serial number or a recoded SFP is rejected

Discussion of why re-coded modules fail Cisco validation: Cisco SFPs carry a unique signature tied to each serial number in bytes 96-127, and editing vendor name or serial makes the signature no longer match, so the switch rejects the module unless the signature is regenerated. Hardware involved…

2votes
1 answer
107views

sfp-eeprom-tool: CH341A-based SFP EEPROM reader and I2C sniffing to expose silent write failures

A small toolset that reads and writes SFP EEPROM over I2C with a CH341A programmer plus an I2C sniffer. The author found that sigrok/PulseView did not work with the analyser, that a v1.0.5 SFP coder firmware reported success while silently not writing the module (proven by I2C traces), and that the…

1vote
1 answer
66views

How the SFP Wizard unlocks modules (part-number database plus brute force) and why not to downgrade the firmware

Reverse-engineering notes on the SFP Wizard: it reads a module's part number (page A0h bytes 40-55), looks it up in an embedded password database and sends the matching unlock password, falling back to brute force when unmatched. It traces the firmware evolution: v1.0.5 tried only the first…

0votes
1 answer
54views

Writing to password-protected SFP/QSFP/XFP: where the password lives and how brute force works

Users needed to write to password-protected SFP/QSFP/XFP modules from HP, Cisco, Finisar and JDSU. The thread documents the two protection levels: a host/user password protecting the user-writable area (A2h offset 7Bh on SFP, A0h offset 7Bh on QSFP/XFP) and a manufacturer password protecting the…

1vote
1comment
32views

Aruba Instant On 1930 24+4SFP: all SFP ports dead after a power outage, LED blinks once and stops

After a power outage an Aruba Instant On 1930 (24 ports plus 4 SFP) still recognised inserted SFP modules but every SFP port stayed down; inserting a new transceiver made the port LED blink once and then nothing. The poster asked for diagnostics or replacement options. Hardware involved: Aruba…

2votes
2comments
111views

Meraki MX95 WAN2 SFP will not link to an Extreme switch (but does to Netgear): power cycle after inserting the SFP

A Meraki MX95's WAN2 SFP would not link to an upstream Extreme switch, while the same SFP and patch linked to a Netgear switch, which in turn linked to the Extreme. The same happened with an MX85 against an AT&T-provided Ciena device. Cisco-certified and Extreme-certified SFPs were tried in all…

Egypt nethawk74 EG asked
4votes
2comments
48views

HL15 (Supermicro X11SPH, Intel X722) to a UniFi USW-24-POE: every DAC and SFP fails, BIOS reports SFP not recognised

A pre-built HL15 server (Supermicro X11SPH-nCTPF wth Intel X722 SFP+ ports, Rocky Linux) would not link to a UniFi USW-24-POE over a VANDESAIL SFP+ DAC: the switch port stayed Disconnected under every negotiation setting on both sides. After ordering a 10Gtek cable the host reported network driver…

1vote
1comment
50views

Cannot write to Finisar SFPs with REVELPROG: manufacturer password protection and per-power-up entry

The poster could read and write OEM SFP variants with a REVELPROG and SFP adapter but not three Finisar references, suspecting manufacturer password protection. Finisar only documents the MSA user-EEPROM password in datasheets, not the proprietary manufacturer password, and the same happened with…

2votes
1 answer
104views

OPNsense 22.7: interface is disabled due to unsupported sfp on a 10G port, and the Linux ixgbe tunable does not apply

After upgrading OPNsense from the 21.x series to 22.7 a 10G SFP+ port stopped working with interface is disabled due to unsupported sfp; the newer Intel driver actively disables unrecognised modules. The poster tried to set ixgbe.allowunsupportedsfp=1 as a system tunable, which was not accepted…