CodingBox Q&A Ask question

Top questions

Popular discussions about programming, compatibility and testing of optical transceivers.

358 questions
15 30 50 per page
0votes
1 answer
82views

Alta Labs Route 10 SFP+ ports detect FS.com and 10Gtek DACs but never link; SR optics work at 10G

On an Alta Labs Route 10 the SFP+ ports recognised FS.com SFP-H10GB-CU2M and 10Gtek CAB-10GSFP-P2M DACs (which had worked on MikroTik CRS devices) but no link came up against a MikroTik CRS309-1G-8S+; forcing 1G baseT full gave a 1 Gbps link only. Staff requested diagnostics and ethtool -I output…

2votes
1 answer
225views

CBS350 SFP-10G-LR link only comes up when the TX fiber is inserted before RX; faulty transceiver pair

While rolling out single-mode fiber between Cisco CBS350-8MGP-2X switches (firmware 3.4.0.17) with SFP-10G-LR modules, the poster hit strange behaviour: the link only comes up if the duplex LC connector is split and the TX fiber is inserted first, then the RX fiber. Inserting the joined LC…

1vote
1comment
72views

SFP Doctor: open hardware/software to read and rewrite SFP OUI and identity when write access is not locked

An open-source hardware and software project to read and modify SFP/SFP+ EEPROM, aimed at changing the OUI and other identity fields so a module works with third-party transceivers where the vendor has not fully disabled write access. It uses a Cypress CY8CKIT-059 board as the USB interface. As of…

3votes
2comments
145views

Genuine Aruba J9151E SFP+ shows Unsupported Transceiver (SelfTest Err#128000) on 2930F switches

On Aruba 2930F switches (JL255A) the poster installed new J9151E 10G SFP+ transceivers (part 1990-4727) that the transceiver guide lists as supported, but every unit was reported as Unsupported Transceiver (SelfTest Err#128000) and show tech transceivers showed ?? for type and serial. J9281D DACs…

2votes
2comments
118views

Intel 82599ES with 10Gtek DACs and transceivers: link flaps up and down on Linux and FreeBSD

Used Intel 82599ES 10-Gigabit SFI/SFP+ NICs from eBay were connected with 10Gtek SFP+ DACs and, via QNAP switches, with 10Gtek SR transceivers over OM3. On Linux dmesg looped NIC Link is Up 10 Gbps / NIC Link is Down; on FreeBSD the interface showed no carrier and DHCP failed. allowunsupportedsfp=1…

3votes
3comments
109views

ethtool -m fails on FS.com XXV710 NIC: "Module EEPROM memory read not supported" and NVM not updatable

On Ubuntu 18.04 (kernel 5.4.0, ethtool 5.3, i40e 2.8.20-k) the poster used 25G XXV710-based NICs bought from FS.com (FS part XXV710AM2-F2, Intel XXV710 chipset). Link and error-free wire-speed traffic worked, but reading a transceiver's DMI data with sudo ethtool -m enp4s0f0 failed with "Cannot get…