Top questions
Popular discussions about programming, compatibility and testing of optical transceivers.
The poster was connecting a Cisco Nexus 93180YC-FX to an Arista 7050SX3 with a 25G AOC sold as Cisco/Arista compatible. The Nexus detects the transceiver, but 'show interface status' reports the port as not connected. A 10G AOC from the same vendor works fine between the two switches, and the same…
One physical server on our ERS 8600 talks to nothing, and the switch is quite convinced everything is fine. The port has been in this state since the server was moved from copper to fibre. Avaya ERS 8600, server on a 1G SFP port in slot 3, port 12 server NIC with its own SFP, fibre patch through…
On a Cisco Nexus N9K-C93180YC-FX, QSFP-40G-SR-BD BiDi modules are not detected at all: nothing appears in the logs when they are inserted and they are absent from 'show interface transceiver', whereas QSFP-40GE-LR4 modules in the same ports are logged and listed normally. Several QSFP-40G-SR-BD…
2votes
2comments
120views
We are moving the office uplinks from copper to fibre and the quote that came back has DrayTek-branded optics in every line. Before I start arguing about the difference against ordinary 10G modules I would like to know whether the hardware actually cares what sits in the cage, because the…
2votes
2comments
112views
I do small business installs, and this one is a fibre service handed off on an ADVA FSP 150-GE102Pro. The customer wants the WAN terminated on their own router instead of the carrier box, so it has to land in the SFP+ cage of a MikroTik RB4011iGS+. Nobody told me what fibre the service actually…
An XCP-ng host with an Intel X520-DA2 and Finisar SFP+ transceivers logged failed to load because an unsupported SFP+ or QSFP module type was detected. insmod with allowunsupportedsfp=1 failed with Unknown symbol in module; options ixgbe allowunsupportedsfp=1 in /etc/modprobe.d/ixgbe-options.conf…
In the poster's data center several Cisco CWDM SFP/GBIC links stopped working: some ports went err-disabled (one with link-flap as the cause) and others simply showed notconnect. Troubleshooting included shut/no shut, reseating the modules, moving the CWDM SFPs to other ports, replacing the patch…
Newly delivered EdgeSwitch ES-24 units linked to each other over gigabit SX SFPs, but the same modules (HP J4858B, J4858A, Avago AFBR-57M5APZ, Avaya AFBR5715PZ, Cisco) would not link ES-24 to HP ProCurve (four models) or Netgear (two models): the ES-24 showed a link light, the other side did not…
On Proxmox VE 6.0 (kernel 5.0.18-1-pve, ixgbe 5.1.0-k) an Intel X520-DA2 exposed ens1f0/ens1f1 but any inserted thirrd-party SFP+ module produced failed to load because an unsupported SFP+ or QSFP module type was detected, and the driver had to be reloaded to detect module changes at all. Hardware…
A T2600G-28TS (TL-SG3424) uplinked over fibre to another building using D-Link transceivers and media converters showed the SFP port UP and transmitting but never receiving packets. Restart, factory reset and other SFP ports were tried. Another user returned the switch after failing to link it to…
The thread starter wanted to reprogram GBIC and SFP module EEPROMs but found that guides were disappearing from forums. Questions covered which programmer to use, where to attach the I2C lines on the module, whether the module needs 5 V (GBIC) or 3.3 V (SFP), and how to treat the memory as a…
An EdgeRouter 4 (EdgeOS 1.10.0) with the GPON SFP taken from a Bell Home Hub 3000 (Huawei MA5671A, SC connector, DDM readable: 50.9 C, 3.25 V, 8.87 mA, TX 1.36 mW, RX 0.02 mW) logged kernel: Failed to read SFP EEPROM1 at byte 0 val -11!! twelve times a minute although the internet worked. Removing…
2votes
2comments
181views
H3C-SFP-10G-T-SO 10GBASE-T copper modules (from FS or Solid Optics) worked out of the box in a FlexFabric 5940 (JH398A) with the JH181A 24-port SFP+ card, but in a FlexFabric 5945 (JQ076A) with the same card the ports only came up after manually running port up-mode on the interface. The poster…
3votes
3comments
205views
The poster wanted to run a link bidirectionally over one strand of single-mode fiber on a Cisco Small Business 300 series switch. Cisco's SMB catalogue lists the MFEBX1 100 Mb BiDi SFP (transmitting at 1310 nm and receiving at 1550 nm), but the poster could not find a Cisco part number for the…
An HP 5900AF-48XG-4QSFP+ (Comware 7.1.045 R2311P01) logged OPTMOD/4/PHONYMODULE: This is not a supported transceiver for this platform for two 10G SR SFP+ modules; display transceiver interface identified them as Avago and JDSU 10GBASESRSFP with DDM. The poster wanted to know which SFP+ to buy and…