Two Cisco Catalyst 3750-X switches (WS-C3750X-24P-L and WS-C3750X-48P-L) run identical code. A Cisco GLC-SX-MMD is detected normally in Gi1/1/1 of the first switch, but the second switch reports 'media type is Not Present' with 'link type is force-up' on Gi1/1/1, and 'show idprom interface Gi 1/1/1' answers '%No module is present'. The same module was tried in several interfaces of both switches. Shut/no shut, reseating, 'service unsupported-transceiver', 'no errdisable detect cause gbic-invalid' and two reloads changed nothing, and no message appeared on the console or in the log. The second switch carries a C3KX-NM-10G network module whose two 10G SFP+ slots are already used for uplinks; the poster was trying to add 1G SFPs in the two remaining slots.

  • Hardware: Cisco Catalyst 3750-X (WS-C3750X-24P-L), Cisco Catalyst 3750-X (WS-C3750X-48P-L), Cisco C3KX-NM-10G network module
  • Transceivers: GLC-SX-MMD, 10G SFP+ (unspecified)
  • Form factor: SFP, SFP+

Symptoms / messages:

media type is Not Present
%No module is present
link type is force-up
SFP detected in one switch but not in another running the same code

Comments 5

Accepted answer

Accepted answer: the C3KX-NM-10G module restricts which combinations of 1G SFP and 10G SFP+ modules can be used across its four slots, which explains why the extra 1G modules are not detected.

tx_eng18
Accepted answer

Per the module specification the supported layouts are: 1G SFPs in all four slots; 1G in slots 1 and 2 plus one 10G SFP+ in slot 4; one 10G SFP+ in slot 2 plus 1G in slots 3 and 4; or 10G SFP+ in slots 2 and 4 only. With two 10G modules installed the remaining slots cannot take 1G SFPs.

tx_eng18

Shut and no shut the interface, reinsert the SFP and watch the console for messages at the moment of insertion.

qsfp_admin

Reload the switch, which often clears such detection problems; the poster reloaded twice without success.

lan_byte59

It might be a software bug; post the full 'show idprom interface Gi 1/1/1' output.

optic_nerd31
Log in to comment. Log in