CodingBox Q&A Ask question

Device support

Programmers, coding boards, switches, NICs and other hardware

204 questions
15 30 50 per page
0votes
1 answer
82views

Alta Labs Route 10 SFP+ ports detect FS.com and 10Gtek DACs but never link; SR optics work at 10G

On an Alta Labs Route 10 the SFP+ ports recognised FS.com SFP-H10GB-CU2M and 10Gtek CAB-10GSFP-P2M DACs (which had worked on MikroTik CRS devices) but no link came up against a MikroTik CRS309-1G-8S+; forcing 1G baseT full gave a 1 Gbps link only. Staff requested diagnostics and ethtool -I output…

1vote
1 answer
54views

Chelsio S320E and a Dell PowerConnect 6224 over a QSFPTEK 0.5 m DAC: no carrier, cable works switch-to-switch

A Chelsio CC2-S320E-SR (110-1114-30) dual-port SFP+ card recognised by TrueNAS would not link to a Dell PowerConnect 6224 through a QSFPTEK 0.5 m passive DAC: no link lights and status: no carrier, even after assigning IPs to cxgb0/cxgb1. Looping the DAC between two switch ports worked, and looping…

2votes
1 answer
65views

OPNsense on a budget C3758R appliance: four ix interfaces, SFP+ ports show down with an RJ45 module

On an inexpensive firewall appliance (Intel Atom C3758R, six 1GbE igc ports and two SFP+ cages wired to the CPU) OPNsense showed four ix interfaces instead of two and the SFP+ ports stayed red/down with a copper SFP+ RJ45 module, although the link LEDs lit. ifconfig -v identified ix0/ix1 as the…

2votes
1 answer
110views

FortiGate 500E shows This port is using a third-party transceiver: warning or error?

A FortiGate 500E displayed the message This port is using a third-party transceiver on an SFP+ port; the poster asked whta it meant and which SFP+ specification to use. There were no errors or link problems, only the log line, so the real question was whether it signals a fault, degrades support…

0votes
0comments
118views

Dell Force10 S4810 warns Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M on a third-party DAC

Monitoring reported packet loss toward an ESXi iSCSI host; on the Dell S4810 (FTOS 9.11(2.6)) the interface TenGigabitEthernet 0/37 showed the warning Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M because a non-Dell DAC was used. The link was up with normal traffic (about 16…

4votes
2comments
152views

Zyxel XGS4600 SFP+ modules randomly stop transmitting after firmware 4.50; DDM shows TX power -inf and 0 mA bias

On Zyxel XGS4600 switches, 10G and 1G SFP+ transceivers (including an FS.com DWDM-SFP10G-80) intermittently stopped transmitting; only removing and reinserting the module restored the link. Transceiver statistics at that moment showed TX power -inf dBm, voltage at the 3.00 V low alarm and TX bias…

France fiberwolf FR asked
1vote
2comments
79views

TP-Link T2600G-28TS SFP port shows UP but receives nothing over fibre to D-Link converters; firmware update fixed it

A T2600G-28TS (TL-SG3424) uplinked over fibre to another building using D-Link transceivers and media converters showed the SFP port UP and transmitting but never receiving packets. Restart, factory reset and other SFP ports were tried. Another user returned the switch after failing to link it to…

0votes
0comments
54views

Cisco-compatible CWDM SFPs that worked in PowerConnect 6024/6224 report transmit failure in an 8024F

Cisco-compatible CWDM SFP modules that had worked in Dell PowerConnect 6024 and 6224 switches produced a transmit failure error in a PowerConnect 8024F, presumably because the 8024F ports are SFP+. The poster considered Finisar FWLF1524P2Vxx modules but wanted confirmation from someone with a…

0votes
0comments
109views

Dell S5212F-ON to Cisco C9500-48Y4C: dual-coded FS SFP28 DACs stay protocol down while 2 m Cisco/Cisco cables link

Between VxRail Dell S5212F-ON TOR switches and Cisco C9500-48Y4C switches, FS.com SFP28 DACs behaved inconsistently: a 5 m cable custom-coded Cisco on one end and Dell on the other came Line Up, Protocol down; a 2 m Cisco/Cisco-coded cable linked; a 3 m cable would not link even with the 2 m…

3votes
2comments
138views

UDM SE recognises a 30 m UACC-AOC-SFP10 but logs an SFP EEPROM error and the Minisforum MS-01 X710 never lights the port

A short no-name DAC between a UDM SE and a Minisforum MS-01 had worked for months; a new 30 m Ubiquiti UACC-AOC-SFP10-30M active optical cable was recognised by the UDM SE (vendor, part, serial, temperrature, power visible) but no link came up and the SFP port log showed an SFP EEPROM error; on…

2votes
1 answer
99views

Connecting a UDM SE 10G SFP+ port to an Enterprise XG 24 SFP28 port: which DAC, and the mixed-speed limitation

The poster wanted to connect a UDM SE (10G SFP+) to an Enterprise XG 24 switch (25G SFP28) and asked whether an SFP+ DAC would work with the SFP28 port falling back to 10G, or whether an SFP28 DAC was preferable. The concern was whether the SFP28 cage would fall back to 10G with an ordinary SFP+…

2votes
2comments
111views

UDM Pro to US-16-150W over a 1 m Ubiquiti DAC: link light on the switch only, even with both ports forced to 1G

A UDM Pro (port 11 set to 1G) and a US-16-150W (port 17) connected by a 1 m Ubiquiti DAC (UDC-1) did not talk: the switch showed a link light, the UDM Pro showed nothing. Setting both sides to 1G and rebooting both devices did not help; reversing the cable and removing the parallel copper uplink…

3votes
2comments
107views

ADDON JD097C-AO DAC links two US-48-500W switches but not the US-16-XG, which still reads the cable EEPROM

An ADDON JD097C-AO SFP+ DAC worked between two US-48-500W (firmware 3.3.11.3850) but not from a US-48-500W to a US-16-XG (3.7.39.6089): no link lights on either side and forcing 10G made no difference, although mca-dump on the XG showed the module fully parsed (sfpfound true, vendor ADDON, part…