The poster was building a server that needed a 1 Gbps single-mode fibre uplink and wanted a PCIe card with two to four SFP cages so any optic could be used later. The core doubt: switches usually accept plain 1G SFP optics in SFP+ ports, but is the same true for 10GbE server NICs, or would the NIC…
The poster's Intel Ethernet Converged Network Adapter X710 would not come up with third-party Fiberxon 10G SFP+ modules: the i40e driver, version 1.2.48, refused to initialise and reported "The driver failed to load because unsupported module type was detected." They asked how to switch on an…
The poster, validating their product against Cisco Nexus 9000 switches (a Nexus C9332D-GX2B chassis), is blocked by bug CSCwo18785: configuring 200G on a QSFP-200G DAC fails with 'ERROR: The transceiver doesn't support this speed'. The cable is a Mellanox MCP1650-H002E26 200GbE DAC; connected…
The poster compiled and loaded i40e 3.4.2 on Ubuntu 16.04 for an Intel XL710-QDA2 dual-port 40GbE adapter. The driver loaded fine, but as soon as non-Intel QSFP+ cables were attached dmesg reported "Rx/Tx is disabled on this device because an unsupported SFP+ module type was detected." and no link…
While rolling out single-mode fiber between Cisco CBS350-8MGP-2X switches (firmware 3.4.0.17) with SFP-10G-LR modules, the poster hit strange behaviour: the link only comes up if the duplex LC connector is split and the TX fiber is inserted first, then the RX fiber. Inserting the joined LC…
4votes
2comments
314views
The poster connects a Cisco Catalyst C9300X-24Y to a FortiGate firewall with a 25G SFP-H25G-CU2M DAC. Whenever the DAC is inserted the switch logs '%PLATFORMPM-6-MODULEINSERTED: SFP module inserted with interface name Twe1/0/23' followed by '%PLATFORMPM-6-DIFFERENTMODULEINSERTED: Warning: SFP…
A Cisco Nexus 5672UP fitted with a 10GBASE-SR SFP+ could not connect to another switch that uses a 1000BASE-SX (1 Gbps) transceiver; both ends are multimode optics. When the poster changed the port speed, 'show interface brief' displayed an 'SFP checksum error', and swapping the Nexus optic for a 1…
On an IOS XR router (RSP-based ASR 9000 class, observed on IOS XR 4.x and 5.x), the poster configured a tunable DWDM XFP with 'controller dwdm 0/1/0/0', 'admin-state maintenance', 'wavelength 55', 'admin-state in-service' and then brought the TenGigE interface up. The running configuration shows…
The poster's newly acquired Cisco Catalyst 9300 (with an 8-port 10G SFP+ network module) would not link to a Cisco Catalyst 4503-E tat only has 1G SFP ports. Suspecting a 10G-versus-1G speed mismatch, the poster tried to force the 9300's 10G SFP to operate at 1G with the 'speed' command, but the…
Two Cisco Nexus 93108TC-FX3P switches on NX-OS 9.3(11) are connected with genuine QSFP-100G-CU1M DACs but the link never comes up. The compatibility matrix says the cable is supported from NX-OS 9.3.5. The port config is a plain 'switchport mode trunk' / 'no shutdown', and 'show interface eth1/54…
3votes
2comments
143views
The poster needs a 100GE link between a Cisco NCS55A2-MOD (NC55-MPA-4H-S MPA) and a Cisco Catalyst C9500-48Y4C using a QSFP-100G-CU1M DAC. Both platforms list the cable as supported, yet the link never comes up at the physical level. Because the Catalyst 9500 lacks 100G auto-negotiation (bug…
The poster was connecting a Cisco Nexus 93180YC-FX to an Arista 7050SX3 with a 25G AOC sold as Cisco/Arista compatible. The Nexus detects the transceiver, but 'show interface status' reports the port as not connected. A 10G AOC from the same vendor works fine between the two switches, and the same…
3votes
3comments
205views
The poster wanted to run a link bidirectionally over one strand of single-mode fiber on a Cisco Small Business 300 series switch. Cisco's SMB catalogue lists the MFEBX1 100 Mb BiDi SFP (transmitting at 1310 nm and receiving at 1550 nm), but the poster could not find a Cisco part number for the…
2votes
2comments
274views
The poster, a new owner of a Cisco Nexus 93180YC-EX running NX-OS 7.0(3)I4(7), cannot bring up any 25G link. ipolex SFP28 DAC cables are recognized ('type is SFP-H25GB-CU1M', 'name is OEM', 'part number is SFP-H25G-CU1M', 'nominal bitrate is 25500 MBit/sec', 'DOM is not supported') but the port…